Motorola RMU2080D manual Display Channel Busy, Lock Out, Silent Mode, Power Up, Audio

Page 90

New Features

 

Programmable Via

Programmable via

 

 

 

 

Advanced

 

 

 

 

 

CPS

 

 

 

Features

Configuration

 

Default Value

 

Programming Tips

 

 

 

 

 

 

 

 

 

 

 

Display

Non-

Display

Non-

 

 

 

 

Display

Display

 

 

 

 

 

 

 

 

 

 

Channel Busy

 

 

 

 

 

 

This feature prevents radio’s transmitter from being

No

No

Yes

 

Yes

OFF

activated if a signal strong enough to break through

Lock Out

 

 

 

 

 

 

 

the noise ‘squelch’ is present.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Silent Mode is only activate when VOX/iVOX is

 

 

 

 

 

 

 

activated.

 

 

 

 

 

 

 

Choices available are:

 

 

 

 

 

 

 

OFF (Default): The radio will work in normal

Silent Mode

No

No

Yes

 

Yes

OFF

 

mode.

 

 

 

 

 

 

 

Accessory Audio Only: Audio is played through

 

 

 

 

 

 

 

 

accessory.

 

 

 

 

 

 

 

No Audio: Audio is disabled even the received

 

 

 

 

 

 

 

 

radio.

 

 

 

 

 

 

 

 

Power Up

No

No

Yes

 

Yes

Tone Only +

Selects the audio the radio will play when it is

Audio

 

Channel

powered up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

88

Image 90
Contents Two-Way Radios Open Source Software Legal Notices Contents Contents Troubleshooting Use and Care Frequency and Code Charts RM UHF Frequencies Chart RMU2080d UHF Default FrequenciesProduct Safety Product Safety and RF Exposure CompliancePackage Contents IntroductionUSA Canada On TTY Text Telephone FCC Licensing Information Interference InformationFCC Licensing Information Batteries Chargers Safety Information Batteries and Chargers Safety InformationBatteries and Chargers Safety Information Radio Overview Parts of the RadioRadio Lithium-Ion Li-Ion Battery Side ButtonsRMU2080d Radio Specifications Battery Features About the Li-Ion BatteryBattery Recycling and Disposal BatteryInstalling the Lithium-Ion Li-Ion Battery Removing the Lithium-Ion Li-Ion BatteryHolster ChargerBattery Life Information Li-Ion Battery Life with Tx Power 2 WattsBattery Meter RM Series Battery MeterBars Charging the Battery Charging with the Drop-in Tray Single Unit Charger SUCTo charge only the battery at on Motorola Authorized BatteriesDrop-in Tray Charger LED Indicators Status LED Indicator CommentsBattery Estimated Charging Time Standard Battery High Capacity BatteryEstimated Charging Time Radio Multi-Unit Charger LED Indicators Radio Overview Started Adjusting VolumeGetting Started Turning Radio ON/OFFSelecting a Channel Talking and MonitoringReceiving a Call Signal Strength Indicator and Channel Busy Indicators Talk RangeIndustrial Multi-Level Getting Started Radio LED Indicators Radio Status LED IndicationWith Compatible VOX Accessories HANDS-FREE USE/VOXPower Up Tone Mode Hands Free without Accessories iVOXToggle Voice Prompt in User Mode Reset to Factory DefaultsSetting VOX /iVOX Sensitivity Keypad Lock/UnlockMenu Options Getting Started Programming Features Advanced Configuration ModeEntering Advanced Configuration Mode Programming RX Reception Frequencies Programming RX Reception Codes CTCSS/DPLProgramming Scramble Programming Maximum Number ChannelsProgramming Call Tones Programming Microphone Gain Level Accessory Gain Level Programming MicrophoneOther Programming Features ScanProgramming Scan List Programming Weather ChannelEditing Channel Alias Name ProgrammingNuisance Channel Delete Customer Programming Software CPSCall Tones Time-Out TimerPower Select ScrambleReverse Burst Weather ChannelPublic Service Band Frequencies MHz National Weather Service. When Noaa Weather AlertCloning Radios Cloning with a Multi Unit Charger MUCFurther details on how to clone radios are CPS and Cloning Cables Optional Accessory CPS CableOperating Instructions What To Do If Cloning Fails Cloning using the Customer Programming Software CPS Troubleshooting SymptomRange. Check for clear line of sight to improve transmission Troubleshooting VOX feature might be set to OFF USE and Care Code Frequency and Code Charts Frequency and ChartsFrequency and Code Charts Frequency and Code Charts RMU2080Dd UHF Default Frequencies Chart Ctcss and PL/DPL Codes PL/DPL Codes 111 Frequency and Code Charts 190 Inverted DPL 200 210 191 201 211 192 202 Frequency and Code United States Warranty forMotorola Limited CanadaAltered Products. Products or Accessories with ExclusionsWHO is COVERED? HOW to Obtain Warranty Service or Other INFORMATION?Software Software Copyright NoticePatent Notice Export LAW AssurancesBattery AccessoriesAudio Accessories CablesCarry Accessories Software ApplicationsAccessories Display Battery SaveButtons Reset Display BacklightChannel AliasingChannels Lock Cloning ModeCPS Manager FrequenciesDisplay Bandwidth IVOX, enableDisable RangeDisplay Keypad Lock LEDs EnabledDisabled Low Battery AlertNuisance Ch Display MicrophoneMonitor DeleteReset to Power SelectPower Up Text DefaultsMultiple TimerDisplay Scan Scan ListVOX, enable VOXDisplay Channel Busy Silent ModePower Up Lock OutPriority Scan Pre-DefinedVoice Prompt Programmable Buttons Chart Icons Chart Signal Strength Vox/IVoxPage 68012009073