Motorola RMU2080D manual Programming Microphone Gain Level

Page 43

Tones’ selection by short pressing the PTT

button or (Menu) button.

The radio display shows the Programming Call Tone’ as follows:

The radio display blinks the current call tone setting. You can select the desired call tone

value (0,1,2 or 3) by pressing the and buttons. Each time you select a different value, your radio sounds the selected call tone (except for value ‘0’).

Once you have selected the desired call tone, long press the PTT button to exit and save, or short press the PTT button to move to the next programming feature without saving.

Note: The values available for Call Tones settings are dependent on the values programmed

via the CPS. Call Tones is disabled when the value is set to ‘0’.

PROGRAMMING MICROPHONE GAIN LEVEL

To configure the Microphone Gain Level, enter the Advanced Configuration Mode and scroll up or down through the programming modes by short pressing the PTT button or (Menu) button until you reach the ‘Microphone Gain Level Programming Mode’.

The radio display shows the Microphone Gain Level as follows:

The radio display blinks the current Microphone Gain Level setting. You can select the desired Microphone Gain Level (1 = low gain, 2 =

PROGRAMMING FEATURES

41English

Image 43
Contents Two-Way Radios Open Source Software Legal Notices Contents Contents RM UHF Frequencies Chart RMU2080d UHF Default Frequencies Troubleshooting Use and Care Frequency and Code ChartsProduct Safety and RF Exposure Compliance Product SafetyIntroduction Package ContentsUSA Canada On TTY Text Telephone Interference Information FCC Licensing InformationFCC Licensing Information Batteries and Chargers Safety Information Batteries Chargers Safety InformationBatteries and Chargers Safety Information Parts of the Radio Radio OverviewRadio Side Buttons Lithium-Ion Li-Ion BatteryRMU2080d Radio Specifications About the Li-Ion Battery Battery FeaturesBattery Battery Recycling and DisposalRemoving the Lithium-Ion Li-Ion Battery Installing the Lithium-Ion Li-Ion BatteryCharger HolsterLi-Ion Battery Life with Tx Power 2 Watts Battery Life InformationRM Series Battery Meter Battery MeterBars Charging with the Drop-in Tray Single Unit Charger SUC Charging the BatteryMotorola Authorized Batteries To charge only the battery at onStatus LED Indicator Comments Drop-in Tray Charger LED IndicatorsStandard Battery High Capacity Battery Battery Estimated Charging TimeEstimated Charging Time Radio Multi-Unit Charger LED Indicators Radio Overview Turning Radio ON/OFF Adjusting VolumeGetting Started StartedTalking and Monitoring Selecting a ChannelReceiving a Call Talk Range Signal Strength Indicator and Channel Busy IndicatorsIndustrial Multi-Level Getting Started Radio Status LED Indication Radio LED IndicatorsHANDS-FREE USE/VOX With Compatible VOX AccessoriesReset to Factory Defaults Hands Free without Accessories iVOXToggle Voice Prompt in User Mode Power Up Tone ModeKeypad Lock/Unlock Setting VOX /iVOX SensitivityMenu Options Getting Started Advanced Configuration Mode Programming FeaturesEntering Advanced Configuration Mode Programming RX Reception Codes CTCSS/DPL Programming RX Reception FrequenciesProgramming Scramble Channels Programming Maximum NumberProgramming Call Tones Programming Microphone Gain Level Programming Microphone Accessory Gain LevelScan Other Programming FeaturesProgramming Weather Channel Programming Scan ListProgramming Editing Channel Alias NameCustomer Programming Software CPS Nuisance Channel DeleteScramble Time-Out TimerPower Select Call TonesWeather Channel Reverse BurstPublic Service Band Frequencies MHz Noaa Weather Alert National Weather Service. WhenCloning with a Multi Unit Charger MUC Cloning RadiosFurther details on how to clone radios are CPS Cable CPS and Cloning Cables Optional AccessoryOperating Instructions What To Do If Cloning Fails Cloning using the Customer Programming Software CPS Symptom TroubleshootingRange. Check for clear line of sight to improve transmission Troubleshooting VOX feature might be set to OFF USE and Care Frequency and Charts Code Frequency and Code ChartsFrequency and Code Charts Frequency and Code Charts RMU2080Dd UHF Default Frequencies Chart Ctcss and PL/DPL Codes PL/DPL Codes 111 Frequency and Code Charts 190 Inverted DPL 200 210 191 201 211 192 202 Frequency and Code Canada Warranty forMotorola Limited United StatesExclusions Altered Products. Products or Accessories withSoftware Copyright Notice HOW to Obtain Warranty Service or Other INFORMATION?Software WHO is COVERED?Export LAW Assurances Patent NoticeCables AccessoriesAudio Accessories BatterySoftware Applications Carry AccessoriesAccessories Display Backlight Battery SaveButtons Reset DisplayAliasing ChannelChannels Frequencies Cloning ModeCPS Manager LockRange IVOX, enableDisable Display BandwidthAlert LEDs EnabledDisabled Low Battery Display Keypad LockDelete Display MicrophoneMonitor Nuisance ChDefaults Power SelectPower Up Text Reset toScan List TimerDisplay Scan MultipleVOX VOX, enableLock Out Silent ModePower Up Display Channel BusyPre-Defined Priority ScanVoice Prompt Programmable Buttons Chart Icons Chart Strength Vox/IVox SignalPage 68012009073