9951 |
|
| When the receiver detects a signal whose level is stronger than the preset |
| level it stops scanning and receives the signal. The setting on system code |
| 9955 is available only when “0” (SQ working condition) is selected here. |
| Setting range: 0 (Squelch working condition is effective as set on code |
| 9955), |
9952 | |
| When a signal is detected, the receiver stops scanning/sweeping and dwells |
| on this channel frequency. When “0” (RX) is selected, the receiver keeps |
| receiving until the traffic goes out of this channel frequency. Define the |
| dwell time between 1 and 99 sec. |
| Setting range: 0 (RX), |
9953 | Sweep width setting range: |
9954 | Sweep step frequency |
| Setting range: |
9955 | Squelch activation |
| “Squelch activation” is the method by which the squelch is activated. |
| Setting range: 0, 1, 2, 3; Factory setting: 3 |
| 0: Voice |
| The squelch is opened by signal frequency less than 1000 Hz (factory set- |
| ting). This frequency can be changed between 500 – 2000 Hz on system |
| code 9958. The loudspeaker reproduces a sound when the signal is lower |
| than the preset frequency. |
| Squelch OPEN: |
| Audio signal is detected and a sound is reproduced through the loudspeaker. |
| Squelch CLOSED: |
| No input signal but only noise is coming into the receiver. The receiver is |
| muted. |
| 1: Level |
| The squelch is activated depending on “signal strength”. The factory setting |
| is “5”. You can change the level between 0 - 10 on system code 9956. |
| 2: And |
| The squelch opens when both “voice” and “signal strength” meet the set- |
| ting. |
| 3: Or |
| The squelch opens by either “voice” or “signal strength”, whichever meets |
| the setting. |
9956 | Squelch level. Setting range: |