Table 14 Alarm Events and Reporting

 

 

 

Reported in

Status LED

Audible

Module

Alarm Event

Alarm LED

event log

on Module

Alarm?

 

 

 

 

 

 

Line Card

Hardware failure

major (red)

major

amber

no

 

 

 

 

 

 

 

Exceeds high temperature limit

major (red)

major

unlit

yes

 

 

 

 

 

 

 

Exceeds warning temperature

minor (amber)

minor

green

yes

 

limit

 

 

 

 

 

Individual interface fails

minor (amber)

reported

amber2

no

 

 

 

 

 

 

RPM (Non-redundant Configuration with 1 RPM)

 

 

 

 

 

 

 

 

 

 

 

Exceeds high temperature limit

major (red)

major

unlit

yes

 

 

 

 

 

 

 

Exceeds warning temperature

minor (amber)

minor

green

no

 

limit

 

 

 

 

 

RPM fails but CP is ok

major (red)

major

amber

yes

 

 

 

 

 

 

SFMs (Redundant Configuration with 10 SFMs)

 

 

 

 

 

 

 

 

 

 

 

Exceeds high temperature limit

major (red)

major

unlit

yes

 

 

 

 

 

 

 

Exceeds warning temperature

minor (amber)

minor

green

no

 

limit

 

 

 

 

 

Any card fails

minor (amber)

minor

amber

no

 

 

 

 

 

 

 

Any card removed

minor (amber)

minor

unlit

no

 

 

 

 

 

 

8 SFMs (Non-Redundant Configuration)

 

 

 

 

 

 

 

 

 

 

 

Exceeds high temperature limit

major (red)

major

unlit

yes

 

 

 

 

 

 

 

Exceeds warning temperature

minor (amber)

minor

green

no

 

limit

 

 

 

 

 

Any card fails

major (red)

major

amber

yes

 

 

 

 

 

 

 

Any card removed

major (red)

major

unlit

yes

 

 

 

 

 

 

1Event appears only in the show alarms command output.

2The interface’s Link LED is unlit.

Power Supplies and Alarms

If a Power Supply fails while the E1200i is operating, the software generates a major alarm and an SNMP trap, lights the major LED, and activates the audible alarm.

When a Power Supply fails, the software also records one alarm event for line cards, RPM, and SFM, though each contains its own power source. The system generates one alarm event and SNMP trap summarizing the Power Supply failure and the components affected.