Remove an AC Power Supply in a non-redundant installation

Step Task

1.Unplug the network interface cables connected to the line card or RPM.

2.Activate the disconnect switch at the Main power source or disconnect the AC cord at the remote power source.

3.Grip the handle and squeeze the thumb latch.

4.Slide the Power Supply out of the slot.

5.If you are replacing the Power Supply, go to Installing AC Power Supplies on page 35.

Remove an AC Power Supply in a redundant installation

Step Task

On/Standby

Switch

AC-Cord Retainer

Safety Cover

Power Supplies

AC Power Plugs

WARNING -

HIGH LEAKAGE CURRENT. EARTH CONNECTION

ESSENTIAL BEFORE CONNECTING SUPPLY.

/ /

COURANT DE FUITE ELEVE. RACCORDEMENT

\

A LA TERRE INDISPENSABLE AVANT LE

/

RACCORDEMENT AU RESEAU.

This retainer must be in place during normal operation.

Do not remove except for servicing

1.Tilt the AC-cord Retainer Safety cover approximately 15o and gently slide the cover away from the chassis.

2.Grip the handle and squeeze the thumb latch.

3.Slide the Power Supply out of the slot.

4.If you are replacing the Power Supply, go to Installing AC Power Supplies on page 35.

Removing and Replacing DC Power Supplies

68

Removing and Replacing Components

Page 68
Image 68
Force10 Networks E1200i Removing and Replacing DC Power Supplies, Remove an AC Power Supply in a redundant installation