Remove an AC Power Supply in a non-redundant installation
Step Task
1.Unplug the network interface cables connected to the line card or RPM.
2.Activate the disconnect switch at the Main power source or disconnect the AC cord at the remote power source.
3.Grip the handle and squeeze the thumb latch.
4.Slide the Power Supply out of the slot.
5.If you are replacing the Power Supply, go to Installing AC Power Supplies on page 35.
Remove an AC Power Supply in a redundant installation
Step Task
On/Standby
Switch
AC-Cord Retainer
Safety Cover
Power Supplies
AC Power Plugs
WARNING -
HIGH LEAKAGE CURRENT. EARTH CONNECTION
ESSENTIAL BEFORE CONNECTING SUPPLY.
/ /
COURANT DE FUITE ELEVE. RACCORDEMENT
\
A LA TERRE INDISPENSABLE AVANT LE
/
RACCORDEMENT AU RESEAU.
This retainer must be in place during normal operation.
Do not remove except for servicing
1.Tilt the
2.Grip the handle and squeeze the thumb latch.
3.Slide the Power Supply out of the slot.
4.If you are replacing the Power Supply, go to Installing AC Power Supplies on page 35.
Removing and Replacing DC Power Supplies
68 | Removing and Replacing Components |