Appendix C

Alarms

 

 

The E1200i generates major and minor alarms for the following conditions:

fan trays status

Power Supply status

RPMs status

high temperature on RPMs

line cards status

high temperature on line cards

SFMs status

high temperature on SFMs.

A major alarm is any fault that would render the E1200i non-functional.

A minor alarm is any fault that threatens the operation of the E1200i.

You can monitor alarm conditions on the E1200i system through the console, you configure the SNMP command (snmp-server enable traps envmon SNMP trap.

LEDs, and audible alarms. If ), the FTOS also sends an

In the E1200i system, alarms are logged for each occurrence, but the system may not send an event log for multiple occurrences. For example, whenever a module exceeds the shutdown threshold, the module shuts down. If more than one module exceeds the warning or high temperature thresholds within a five minute period, the system generates one event for all effected modules, but alarms are logged for each occurrence. If the modules temperature falls to 5° lower than the warning threshold temperature, the system clears the alarm and an SNMP trap.

Table 14 Alarm Events and Reporting

 

 

 

Reported in

Status LED

Audible

Module

Alarm Event

Alarm LED

event log

on Module

Alarm?

 

 

 

 

 

 

Fans

Entire Fan Tray fails

major (red)

major

unlit

yes

 

 

 

 

 

 

 

1 or 2 individual fans fail

minor (amber)

minor

unlit

no

 

 

 

 

 

 

Power

Power Supply input power fail

major (red)

major

unlit

yes

Supply

 

 

 

 

 

Power Supply power fails at boot1

unlit

not reported

unlit

no

 

 

 

 

 

 

 

Installing and Maintaining the E1200i System