Aiphone IS Series Making detailed settings to master stations, Settings on Other window

Page 15

BSettings on [Contact input] window (for room sub stations only)

Make settings for contact input.

[Contact type]:

Select either Normally open (NO) or Normally closed (NC).

[Call priority/Answering the page]:

You can select the action of the station when detecting input between ‘calling with appropriate priority’ and ‘answering the page’.

Select “Normal”, “Priority”, “Urgent” or “Answering the page”.

Close

Click this to close the current window and return to the previous window.

CSettings on [Other] window

[Transmit volume boost at PTT]:

Select whether to increase the press-to-talk sound volume transmitted to the stations (ON) or not (OFF).

[Camera zoom image preset] (video door stations only):

Select the default of camera’s Zoom/Wide function at calling from the 9 zoom positions and "0" (wide) from the pull-down menu.

[Call acknowledge tone on/off]:

Select whether to sound the call acknowledge tone of door station or room sub station (ON) or not (OFF).

[Backlight adjustment] (video door stations only): Select the method of adjusting the backlight in the daytime between “Exposure +” and “Exposure –”.

[Speaker] (room sub stations only):

Select the speaker to be used between “Built-in speaker” and “External speaker”.

*When “External speaker” is selected, no sound will be output from the built-in speaker.

Close

Click this to close the current window and return to the previous window.

About the priority

When receiving two or more functions (communication, calling, paging, monitoring, etc.) at the same time, depending on the priority setting, the order of priority for them is as follows.

Priority

Setting

Function

1 (high)

[Urgent]

Communication, calling,

2

[Priority]

paging, chime paging

3[Normal]

4 (low)

-

Monitoring, scan-monitoring

Making detailed settings to master stations

The following setting item buttons are displayed in the “Advanced settings” window.

D

E

*Click either the button D or E to open the corresponding setting window, and then make the settings in the displayed window(s). See the detailed

instructions for D or E below.

*Click Close to close the current window and return to the previous window.

DSettings on [Stations to be scan monitored] window

Set the scan-monitoring target sub station(s).

*Up to 20 sub stations can be set.

1Click Reference to open another window, then select the target stations, and then click Close to return to the previous window.

The selected stations are added and displayed in the list.

*To delete a station (or stations) from the list, check the target station(s) in the list and click Delete .

2Repeat step 1 to register more stations.

3Click Close to close the current window and return to the previous window.

ESettings on [Other] window

[Master station function: paging, chime, monitor, door release, and remote site call]:

Select whether to enable the following functions of master station (ON) or not (OFF).

Starting paging

Starting chime paging

Monitoring/scan-monitoring

Releasing door

Remote site call (standard (IP) system only)

Close

Click this to close the current window and return to the previous window.

GETTING STARTED SETTING THE SYSTEM USING THE SYSTEM

APPENDIX

15

Image 15
Contents Setting Manual Contents Purpose of the System Settings About this ManualManual configurations Dhcp Setting ListON/OFF Title Sub titleDS1 SS1DT1/DT2 NTPJAN Connect a PC to the central control unit When connecting a PC to the central control unitStarting UP the System System requirements for PCStart up the PC, and then open the browser window Setting the system configuration System configurationLog in to the system by setting the following items Password Enter aiphoneBasic setting procedure Making the System SettingsStatic IP Address Making network settings Network settingSelecting the network setting method Dhcp Registering areas System setting Area registration Required Registering zones System setting Zone registration Click Control units composition in the table of contents Other buttons How to select multiple stationsSetting the station no. is required Collective settingSettings on Called stations setting window Basic setting procedureClick Advanced station settings in the table of contents When you have finished making all the detailed settingsSettings on Stations to be scan monitored window Making detailed settings to master stationsSettings on Contact input window for room sub stations only Settings on Other windowSelect an output terminal from the pull-down menu Settings on Contact output windowSound file specifications Click Registering sound source in the table of contentsClick Registering daily chime schedule in the table Chime setting Registering daily chime scheduleClick Registering sound sequences in the table of contents Registering daily chime scheduleDownloading chime schedule data Click Chime schedule setting in the table of contentsSettings on Weekly schedule setting window Settings on Individual schedule setting windowClick Registering daily transfer schedule Click Transfer schedule setting in the table of contentsSetting the timer Timer setting When uploading setting data Setting time and date Time and date settingDownloading/uploading setting data Setting file When downloading setting data onto the PCMaintenance