Panasonic KX-TCD951EB operating instructions

Page 3

a)This apparatus may be used on telecommunication systems employing LD and MF signalling. It is suitable for connection to a direct exchange line on the PSTN (Public Switched Telephone Network) or via a compatible PBX (Private Branch Exchange). (Contact the supplier for an up to date list of compatible PBX’s.)

b)This apparatus is not suitable as an extension to a payphone or for use on a party line with shared service.

This cordless telephone has been designed to operate on radio frequencies which have been assigned to the exclusive use of cordless telephones. As the use of cordless telephones becomes more widespread users may experience a reduction in the quality of service obtainable from this apparatus.

Although this equipment can use either loop disconnected or DTMF signalling, only the performance of the DTMF signalling is subject to regulatory requirements for correct operation. It is therefore strongly recommended that the equipment is set to use DTMF signalling for access to public or private emergency services. DTMF signalling also provides faster call set up.

999 or 112 can be dialled on the apparatus for the purposes of making outgoing calls to the BT Emergency (999 or 112) Service.

WARNING:

The apparatus may be unable to make emergency 999 or 112 telephone calls, under certain conditions, e.g.

Radio interference caused by another cordless telephone operating on the same radio frequency.

The portable handset battery needs recharging, or has failed.

The portable handset cannot be used while charging.

Any cases of difficulty should be referred in the first instance to the supplier of the apparatus.

NOTE:

If you experience any problems with the normal use of your apparatus, you should unplug it from the telephone outlet and connect a known working telephone in its place. If the known working telephone still gives problems, then please contact the customer service department of your PSTN operator. If it operates properly, then the problem is likely to be a fault in your apparatus. In this case, contact your supplier for advice. Your PSTN operator may charge you if they attend a service call that is not due to apparatus supplied by them.

3

Image 3
Contents Charge the batteries for about 4 hours before initial use Operating InstructionsImportant Information Ringer Equivalence Number RENMethod of connection Page Before Initial Use Battery Charge For Best PerformanceBase Unit Location Contents Correct Use and Charging Selecting the Stand-by ModeLocation of Controls Base unitHandset Icons SettingsInstalling the Batteries in the Handset DisplayUSE only with Panasonic AC Adaptor KX-TCA9E or KX-TCA11E Settings ConnectionsHooks To Mains Outlet AC 230-240 V, 50 Hz Telephone Line CordFully charged Medium Low Battery strengthBattery information RechargeCurrent connected base unit number is displayed Settings Turning the Power onDisplay Power Button PWR Press P W RPress Selecting the Dialling ModePress Prog then I N T Enter the base unit password Ensure that the dialling mode is selected toneRinger pattern Settings Selecting the Handset Ringer Volume/PatternRinger volume F23UPress Prog then I N T Press 2 Twice Selecting the Base Unit Ringer VolumePress the desired volume level 1 , 2 , 3 or 22u2888800 00 To select the receiver volumeMaking Calls I2345678To turn the handset ringer off temporarily Answering CallsTo redial the last number dialled To redial after confirming the numbers in redial memoryTo erase a stored number Speed DiallingStoring Phone Numbers in Memory Dialling a Stored NumberPress Prog then I N T Enter the base unit password p Special FeaturesHow to Use the Pause Feature Setting the pause timingTo cancel the key lock Special Features Handset LocatorSetting the Key Lock For Rotary or Pulse Service UsersTo accept the waiting call and hang up the existing call Using the Recall FeatureSelecting the earth option/time break recall mode 32uSummary of Programmable Functions 5o - - o Setting the PasswordF5o F5o - - oF42 Setting the Direct Call ModeTo turn OFF the direct call mode Direct CallF4 IO0 To turn OFF the call prohibition modeCall Prohibition F4 IoCall Restriction To cancel the call restricted handsetsTo cancel the call restriction numbers When you dial a restricted numberF26U Other Programmable SettingsF2 iU F25U0I234567890 Other Programmable Settings Selecting the Talk Mode DisplayPress G or F to select to select the desired setting F32UFunction Clearing the Settings in MemoryFor Optional Multi-Unit Users Operating More than One HandsetOperating More than One Base Unit Registering a Handset in the Base Unit RegistrationF7 iU F7 ioI000 Registration Selecting the Base Unit AccessAutomatic base unit access Specified base unit accessPress O K Enter the handset password p Cancelling a HandsetCancelling a base unit Enter the handset numbers you want to cancelIu2 Selecting the Stand-by Mode DisplayBell Selection F3 i0Selecting all handsets Iu3I03 i23456 Selecting first handsetIntercom between Handsets Paging/Intercom888800 00 0 Paging All Handsets from the Base UnitTransferring a call using the intercom Transferring a Call from One Handset to AnotherTransferring a call without the intercom Press Prog Press G or F until F24 is displayed Press O K Setting the Call Waiting ToneF24U Paging/Intercom ConferenceReplaceshown. the batteries with new ones as Replacing the BatteriesUsing the Belt Clip Replacing the BatteriesTo remove the belt clip Problem Remedy Before Requesting HelpUnit does not work You cannot redial Be included when rediallingBefore Requesting Help Does not functionYou cannot register the handset in the base unit Placement Safety InstructionsSafety Installations EnvironmentAdding Another Phone Term Definitions Serial No Panasonic Business Systems U.KReceipt No Date of Purchase Model No. KX-TCD951EBSales Department Panasonic Business Systems U.K ManufacturerPQQX12191ZB-UK WU0699MK2079