Panasonic KX-TCD951EB Selecting the Stand-by Mode Display, Bell Selection, F3 i0, Iu2

Page 34

Selecting the Stand-by Mode Display

You can choose whether to display the currently connected base unit number, handset number or no display while in the stand-by mode. The factory preset is the base unit number.

1Press PROG .

2Press G or F until “F3 i ” is displayed, then press O K .

The current setting is displayed. 1: Base unit number

2: Handset number 0: No display

F3 i0 i

3Press G or F to select the desired setting.

You can press 1 , 2 or 0 to select the setting.

4Press PROG .

A confirmation tone sounds and the display will return to the stand-by mode. Ex. Handset number is selected.

[ 2 ]

Bell Selection

There are three choices for bell selection. When a call is being received:

all handsets ring. “All handsets”

the selected handset(s) ring(s). “Specified handset(s)”

the selected handset rings first, then if it does not answer, all other handsets will ring. “First handset”

The factory preset is “All handsets”. To change the bell selection, program as follows.

Selecting specified handset(s)

You can choose which handset(s) you want to ring.

1Press PROG then I N T .

2Press 1 .

3Enter the base unit password (p. 23).

The current setting is displayed. 1: All handsets

2: Specified handset(s)

3: First handset

Ex. All handsets is selected.

iu i

34

4 Press 2 .

The current registered handset number(s) is/are displayed.

Ex. Handset 1, 2, 3, 4, 5 and 6 are registered.

iu2 - i23456

5Enter the handset number(s) you want to ring.

The selected handset number(s) flash(es).

If you misdial, press the number(s) again.

6Press PROG .

A confirmation tone sounds and the display will return to the stand-by mode.

Image 34
Contents Operating Instructions Charge the batteries for about 4 hours before initial useRinger Equivalence Number REN Important InformationMethod of connection Page Before Initial Use For Best Performance Battery ChargeBase Unit Location Contents Selecting the Stand-by Mode Correct Use and ChargingBase unit Location of ControlsHandset Display SettingsInstalling the Batteries in the Handset IconsTelephone Line Cord Settings ConnectionsHooks To Mains Outlet AC 230-240 V, 50 Hz USE only with Panasonic AC Adaptor KX-TCA9E or KX-TCA11ERecharge Battery strengthBattery information Fully charged Medium LowPress P W R Settings Turning the Power onDisplay Power Button PWR Current connected base unit number is displayedEnsure that the dialling mode is selected tone Selecting the Dialling ModePress Prog then I N T Enter the base unit password PressF23U Settings Selecting the Handset Ringer Volume/PatternRinger volume Ringer pattern22u2 Selecting the Base Unit Ringer VolumePress the desired volume level 1 , 2 , 3 or Press Prog then I N T Press 2 TwiceI2345678 To select the receiver volumeMaking Calls 888800 00To redial after confirming the numbers in redial memory Answering CallsTo redial the last number dialled To turn the handset ringer off temporarilyDialling a Stored Number Speed DiallingStoring Phone Numbers in Memory To erase a stored numberSetting the pause timing Special FeaturesHow to Use the Pause Feature Press Prog then I N T Enter the base unit password pFor Rotary or Pulse Service Users Special Features Handset LocatorSetting the Key Lock To cancel the key lock32u Using the Recall FeatureSelecting the earth option/time break recall mode To accept the waiting call and hang up the existing callSummary of Programmable Functions F5o - - o Setting the PasswordF5o 5o - - oDirect Call Setting the Direct Call ModeTo turn OFF the direct call mode F42F4 Io To turn OFF the call prohibition modeCall Prohibition F4 IO0When you dial a restricted number To cancel the call restricted handsetsTo cancel the call restriction numbers Call RestrictionF25U0 Other Programmable SettingsF2 iU F26UF32U Other Programmable Settings Selecting the Talk Mode DisplayPress G or F to select to select the desired setting I234567890Clearing the Settings in Memory FunctionOperating More than One Handset For Optional Multi-Unit UsersOperating More than One Base Unit F7 io RegistrationF7 iU Registering a Handset in the Base UnitSpecified base unit access Registration Selecting the Base Unit AccessAutomatic base unit access I000Enter the handset numbers you want to cancel Cancelling a HandsetCancelling a base unit Press O K Enter the handset password pF3 i0 Selecting the Stand-by Mode DisplayBell Selection Iu2Selecting first handset Iu3I03 i23456 Selecting all handsetsPaging All Handsets from the Base Unit Paging/Intercom888800 00 0 Intercom between HandsetsTransferring a Call from One Handset to Another Transferring a call using the intercomTransferring a call without the intercom Paging/Intercom Conference Setting the Call Waiting ToneF24U Press Prog Press G or F until F24 is displayed Press O KReplacing the Batteries Replaceshown. the batteries with new ones asReplacing the Batteries Using the Belt ClipTo remove the belt clip Before Requesting Help Problem RemedyUnit does not work Does not function Be included when rediallingBefore Requesting Help You cannot redialYou cannot register the handset in the base unit Installations Environment Safety InstructionsSafety PlacementAdding Another Phone Term Definitions Model No. KX-TCD951EB Panasonic Business Systems U.KReceipt No Date of Purchase Serial NoManufacturer Sales Department Panasonic Business Systems U.KPQQX12191ZB-UK WU0699MK2079