| Help |
N Sub monitor station/Battery |
|
|
|
|
|
Problem | Cause & Solution | Page |
flashes and 2 short beeps | LThe battery level is low. Charge the battery immediately. | 16 |
sound. |
|
|
|
|
|
Even if you place the sub monitor | LThe AC adaptor is disconnected from the power outlet or | 16 |
station on the charger, the | the charger. Plug the AC adaptor into the power outlet or the |
|
CHARGE indicator does not light | charger firmly. |
|
up. | LThe sub monitor station is not placed on the charger correctly. | 16 |
| Replace it securely. (A short beep sounds and the CHARGE |
|
| indictor lights in solid red.) | 52 |
| LThe charge contacts are dirty. Clean them with a soft, dry cloth. | |
| LThe battery is new or discharged. Place the sub monitor station | 16 |
| on the charger and wait for a few minutes. |
|
|
|
|
The CHARGE indicator does not | LWhen the power of the main monitor station is turned off or | 16 |
go off after the battery has been | “OUT OF RANGE” is displayed on the sub monitor station, the |
|
charged for about 7 hours. | charging time will become longer. Make sure the power of the |
|
| main monitor station is turned on, and charge the sub monitor |
|
| station in a location near the main monitor station where “OUT |
|
| OF RANGE” disappears. |
|
|
|
|
Even if the sub monitor station | LThe battery is at the end of its life. Replace the battery with a | 52 |
has been charged, flashes | new one. |
|
after using it a few times. |
|
|
|
|
|
The sub monitor station, the AC | LThis is normal. (It may feel a little warmer in summer than in | ― |
adaptor, or the charger is warm. | winter.) If it feels very hot, disconnect the AC adapter from the |
|
| power outlet and contact our service personnel. |
|
|
|
|
N Others |
|
|
|
|
|
Problem | Cause & Solution | Page |
The main monitor station, the | LThe unit does not work during a power failure. The date and | 17 |
sub monitor station, and the | time may be reset to the default setting after a power failure. In |
|
door station do not work during a | this case, set the date and time using the main monitor station |
|
power failure. | again. |
|
|
|
|
L“DEMO MODE” is displayed. | LDemo mode is activated. Change the setting to “OFF”. | 39 |
LYou cannot answer the call or |
|
|
make an intercom call. |
|
|
|
|
|
LThe unit does not work with | LPerform the following operation (Reset). |
|
correct operations. | Main monitor station: | 10 |
LThe unit does not work properly. | Press the RESET switch on the bottom of the main monitor | |
| station with a pointed object. (Recorded images and the |
|
| program settings are not affected.) |
|
| Sub monitor station: | ― |
| Remove the battery and insert it again. | |
| – Program settings are not affected. |
|
| – is displayed. However, the actual battery level is |
|
| maintained. |
|
|
|
|
49
SW250BX_OI.indb 49
2010/08/25 15:58:39