EFJohnson 7780 service manual Tone ENABLE/DISABLE, Scanning

Page 20

TRANSCEIVER OPERATION

channel it can be programmed for times from 15 seconds up to 3 minutes, 45 seconds or disabled (not used). If the transmitter is keyed continuously for longer than the programmed time, the transmitter is disabled and an invalid condition tone sounds. Five seconds before time-out occurs, an alert tone sounds to indicate that time-out is approaching. The timer and tone are reset by releasing the PTT switch.

One use of this feature is to prevent a channel from being kept busy for an extended period by an accidentally keyed transmitter. It can also prevent possible transmitter damage caused by transmitting for an excessively long period. Conventional channels can also be programmed with the Penalty and Conversa- tion timers that are described in Sections 2.4.7 and 2.4.8.

2.3.10 TONE ENABLE/DISABLE

The supervisory tones (see Section 2.6) can be enabled and disabled by the Tones On-Off option switch if it is programmed. When tones are enabled by this switch, “TONE ON” is momentarily displayed and a tone sounds. Conversely, when tones are disabled, “TONE OFF” is displayed and no tone sounds. If the Tones On-Off option switch is not programmed, tones are fixed in the on or off mode by programming.

2.3.11 SCANNING

Introduction

Scanning cycles through a list of channels, called a “scan list”, checking each for messages. When a message is detected that your transceiver is programmed to receive, scanning stops and the message is received. Shortly after the message is complete, scanning resumes (unless it has been disabled).

There are two basic scan modes: Standard and Radio Wide. The Standard mode is unique to the type of channel selected (conventional or SMARTNET/ SmartZone), and the Radio Wide mode is the same regardless of the channel type selected. Only one of these scan modes can be enabled at a time. Therefore, if standard scanning is enabled while radio wide scan- ning is occurring, radio wide scanning is automatically

disabled and vice versa. More information on these modes follows.

Standard Scanning

Standard scanning monitors only channels that are the same type as that currently selected. There- fore, if a conventional channel is selected, only conventional channels are scanned, and if a SMARTNET channel is selected, only SMARTNET channels are scanned. Standard scanning is turned on and off by the Scan option switch as follows. If this switch is not programmed, standard scanning is not available.

To turn standard scanning on, press the Scan option switch. Scanning is enabled when the “ S” icon is indicated in the upper left corner of the display and SCAN x (conventional) or SCAN ON (SMARTNET/SmartZone) is briefly displayed. The “x” is the number of the conventional scan list (1, 2, or 3) that is selected. Refer to Section 2.4.11 for more information.

To turn scanning off, press the Scan option switch again. The “ S” icon is then no longer indicated and “SCAN OFF” is briefly displayed.

If the zone or channel is changed while scanning is selected, scanning continues on the same or a different scan list (see scan list information which follows).

Radio Wide Scanning

Radio wide scanning monitors the channels in the preprogrammed radio wide scan list (see information which follows). This list may contain up to 16 chan- nels of any type (conventional or SMARTNET/Smart- Zone) assigned to any zone. Radio wide scanning is turned on and off by the Radio Wide Scan option switch as follows. If this switch is not programmed, radio wide scanning is not available.

To turn radio wide scanning on, press the Radio

Wide Scan option switch. The icon is then displayed continuously and “RWS ON” is displayed

briefly.

November 1999

 

Part No. 001-7780-500

2-6

Image 20
Contents 7780 Page Page Table of Contents Table of Contents CONT’D List of Tables List of FiguresGeneral Information Scope of Manual Equipment DescriptionAccessories Factory Customer ServicePart Number Breakdown Transceiver IdentificationAccessories AccessoryToll-Free 800 Factory ReturnsDefinitions Replacement PartsInternet Home Intrinsically Safe Information Temperature Code T3C Possible Ignition SourcesIntrinsically Safe and Nonincendive Ratings Classification of Hazardous Areas and AtmospheresAccessing PC Boards Material ClassificationTypical Hazard Group Class Area ClassificationRemoving RF Unit Removing Logic UnitSpecifications GeneralControls and Display FeaturesTransceiver Operation TX Indicator Red Indicates when the transmitter is keyed Low-Battery Indicator AmberDisplay DisplayFront Panel Keys Full Keypad Model Turning Power on and Setting Volume Option SwitchesGeneral Operation BacklightSee Option Switch FunctionsFunction Conv Tone ENABLE/DISABLE ScanningConventional and SMARTNET/ Smartzone Operation Monitoring Before Transmitting Conventional FeaturesDisplay Mode Selection Call Guard Squelch Monitor ModeBusy Channel Lockout Penalty Timer Conversation TimerPower Output Select Conventional Mode ScanningPriority Channel Sampling DTMF/ANI Signaling Standard Conventional CallsSMARTNET/SMARTZONE Features Viewing Unit IDStandard Group Calls Enhanced Private Conversation CallsTransceiver Operation Private Conversation II Calls Telephone Calls Call Alert Sending Status Conditions Emergency Alarm and CallMessaging Dynamic Regrouping Failsoft OperationSMARTNET/SMARTZONE Scanning Supervisory Tones Zone Change Parameter Keypad ProgrammingMenu Description Channel Parameters Channel Change ParameterSystem Parameters Programming Setup Pctrunk Software InstallationTransceiver Programming Computer DescriptionConnecting RPI to Computer and Transceiver Starting and ExitingProgramming File Types Help FilesScreen Pop-Up Buttons and File Size Indicator Programming ProcedureFile Size Indication Creating and Displaying SystemsMenu Commands Menu BarRadio Type Menu Download Menu Upload MenuSystems Menu Window MenuDefaults RADIO-WIDE Parameter ScreensBand ZonesRadio Wide Scan List Radio-Wide Scan List ScreenModify List Screen Assign Function ButtonsRADIO-WIDE Conventional Screen RADIO-WIDE SMARTNET/SMARTZONE ScreenFull Spectrum CC Scan Hot DtmfAdjustable Parameters RADIO-WIDE Portable Options ScreenProgramming Conventional Systems and Channels Conventional System General ScreenTimers Conventional System Modify Scan List ScreenKeypad Editing Scan List ButtonPriority Channel Selection Scan TimersSetting UP Conventional Channels Conventional Channel Screen Parameters Selected ChannelTransmit Power SignalingChannel Type Tx Time-OutRestricted Access Time-Out TimerISW Delay Time Splinter ChannelsSMARTNET/SMARTZONE System Other ID’S Screen SMARTNET/SMARTZONE System Phone Interconnect ScreenPhone Interconnect Private CallSMARTNET/SMARTZONE System Emergency Settings Screen Emergency AlarmSMARTNET/SMARTZONE System Talk Groups Screen Failsoft ChannelMessage Aliasing Screen SMARTNET/SMARTZONE System Lists ScreensTrunking Phone List Screen Announcement Groups Screen Control Channels ScreenTrunking Call List Screen SMARTNET/SMARTZONE Channel Screen Parameters Setting UP SMARTNET/SMART- Zone ChannelsStatus Aliasing Screen SMARTNET/SmartZone Channel Screen Other Screen ParametersCall Guard CTCSS/DCS Codes and Tones Recommended Tone Call Guard Codes FreqMHz Channels MHz Channels MHz Channels MHz Channels MHz Channels MHz Channels Power Switching and Regulation Power SwitchingCircuit Description Synthesizer DescriptionCharge Pump Q1, Q2, Loop Filter VCO and Tcxo ModulationSynthesizer Chip IC1 If Amplifier Q2, LIMITER/DETECTOR IC3 Receiver Circuit DescriptionRF Amplifier Q1, First Mixer Q2 Antenna Switch and LOW-PASS Filter Squelch Circuit IC4A/B, IC5ATransmitter Description Amplifier Q9, Driver Q8Control Logic and Display Receive Audio ProcessingMicroprocessor IC306 Pin Descriptions Pin Port Name Input or Description Active High OutputHvfulswlrq Receive Data FILTER/DETECTOR IC102A/B, IC107A/B Audio Amplifier IC104-IC106Receive and Transmit Data Processing Transmit Data Filter IC206B/ IC206A Transmit Audio ProcessingLOW-PASS Filter IC205A/B Smartnet Data ProcessingBattery Pack and Charger Information Battery PackPower Setting Operating Time Function Fahrenheit CelsiusBattery Pack and Charger Information Alignment Procedure and Performance Tests Test SetupTune Software Hqhudo Mm/3/32 Mm/1/8 Phone JackPreliminary Setup Main Pctune ScreenTransmit Frequency and Power Transmit Power Adjustment ScreenHigh Power Level = 3.0 watts Low Power Level = 1.0 watt Modulation BalanceSquelch Adjust Rssi AdjustAudio Deviation Data DeviationPerformance Tests Receiver Performance TestsPower Output Transmitter Performance TestsTransmit Frequency Transmit ModulationThis page intentionally left blank Parts List Display AssemblyChassis Parts Ref No DescriptionKEY Assembly Display AssemblyIf Assembly If AssemblyKEY Assembly PLL Assembly RF UnitRF Unit NJM2904V-TE1 IC RF Unit Logic Unit Logic Unit TDA7233D IC Logic Unit 200K ERJ3GE MP35 MP18 MP25 KEY Front Panel EP2EP1 MP32 MP33 MP27 MP34 MP28 MP29 MP23 MP22 MP30 MP24 MP26 MP18 PLL Board Bottom View Schematic Diagrams and Component LayoutsPLL Board TOP View If Board TOP View If Board Bottom ViewTransceiver Block Diagram RF UnitRF Board TOP View MICRF Board Schematic If AMPLogic Board TOP View HD1Logic Board Schematic Receive Audio ProcessingDisplay Board Bottom View GND KEYR3 KEYR2 KEYR1 KEYR0 KEYS3 KEYS2 KEYS1 KEYS0 GNDDisplay Board Schematic DS3 DS4 DS5KEY Board Front View KEY Board Back ViewKEY Board Schematic S S R R R RScan HC2 HC7 HC8 HC3 Schematic Diagrams and Component Layouts