EFJohnson 7780 service manual Transceiver Operation

Page 28

TRANSCEIVER OPERATION

2.Enter the index of the desired ID if you know it or

scroll through the list using the and keys until you find the desired ID. Press the CLR key to cancel the call.

3.Press the PTT switch or the ENT key to initiate the call. The display then indicates the alias of the desti- nation radio. Proceed to the bulleted list following the next method for conditions that may occur next.

Direct Entry Method (Full Keypad Models Only)

1.With a SMARTNET/SmartZone channel selected, press and hold the Private Call option switch until a tone sounds (approximately 1 second). The last ID called is displayed, and the private call mode is indi- cated by “ C” in the upper part of the display.

2.Using the 0-9 keys, enter the 6-digit ID of the

mobile unit you are calling. Press the key to erase the last digit entered or press the CLR key to

cancel the call.

3.Press the PTT switch or the ENT key to initiate the call. If the entered ID is invalid, “INVALID” is momentarily displayed and the call is not initiated. If the entered ID is valid, the display indicates the alias of the ID if it matches an ID in your call list. Otherwise, the ID you entered continues to be displayed. Any of the following conditions may then occur:

If the radio you are calling is on the air, telephone type “ringing” is heard for 20 seconds or until the called party answers.

If the called party answers and the call is successful, the person’s voice is heard and the call is carried on the same as a group call. To end the call at any time, press the CLR key.

If the called party does not answer within 20 seconds, “NO ANSWR” is displayed and a continuous tone sounds. End the call by pressing the CLR key.

If the called radio is not in service, no ringing is heard, “NO ACK” is displayed, and a continuous tone sounds. End the call by pressing the CLR key.

If neither your radio nor the radio being called is authorized to make unit-to-unit calls, “REJECT” is displayed and a continuous tone sounds. End the call by pressing the CLR key.

If the called party answers but the radio system is busy, four low tones sound and “BUSY” and “WAIT” are alternately displayed. When the system is no longer busy, the called party auto- matically responds.

If an out-of-range condition exists or the radio system is not in service, “LOST CALL” is displayed and a continuous tone sounds. End the call by pressing the CLR key.

Receiving an Enhanced Private Conversation Call

These calls are automatically received if a SMARTNET/SmartZone channel is selected. Proceed as follows:

1.When a call is received, a recurring unit call tone (three beeps) sounds for up to 20 seconds, and “CALL RCV” and the current channel alias are alternately displayed.

2.To answer the call, press the Private Call option switch and then the PTT switch and begin talking. The private call mode is indicated by “ C” in the upper part of the display. The alias of the incoming call is displayed if the ID is in your call list. Other- wise, the unit ID is displayed. NOTE: If the Private Call option switch is not pressed before the PTT switch, a group call is transmitted on the selected group.

To end the call when the conversation is complete or at any other time, press the CLR key.

If unit-to-unit (private) calls are not permitted (Private Call switch not programmed), press the Call Response option switch, if available, to answer the call.

If the call is not answered within 20 seconds, it is automatically terminated.

If the radio system is busy, four low tones sound and “BUSY” and “WAIT” are alternately

November 1999

 

Part No. 001-7780-500

2-14

Image 28
Contents 7780 Page Page Table of Contents Table of Contents CONT’D List of Tables List of FiguresGeneral Information Scope of Manual Equipment DescriptionAccessories Factory Customer ServicePart Number Breakdown Transceiver IdentificationAccessories AccessoryToll-Free 800 Factory ReturnsInternet Home Intrinsically Safe Information Replacement PartsDefinitions Temperature Code T3C Possible Ignition SourcesIntrinsically Safe and Nonincendive Ratings Classification of Hazardous Areas and AtmospheresAccessing PC Boards Material ClassificationTypical Hazard Group Class Area ClassificationRemoving RF Unit Removing Logic UnitSpecifications GeneralTransceiver Operation FeaturesControls and Display TX Indicator Red Indicates when the transmitter is keyed Low-Battery Indicator AmberFront Panel Keys Full Keypad Model DisplayDisplay Turning Power on and Setting Volume Option SwitchesGeneral Operation BacklightFunction Conv Option Switch FunctionsSee Tone ENABLE/DISABLE ScanningConventional and SMARTNET/ Smartzone Operation Display Mode Selection Conventional FeaturesMonitoring Before Transmitting Busy Channel Lockout Monitor ModeCall Guard Squelch Penalty Timer Conversation TimerPower Output Select Conventional Mode ScanningPriority Channel Sampling DTMF/ANI Signaling Standard Conventional CallsSMARTNET/SMARTZONE Features Viewing Unit IDStandard Group Calls Enhanced Private Conversation CallsTransceiver Operation Private Conversation II Calls Telephone Calls Call Alert Messaging Emergency Alarm and CallSending Status Conditions SMARTNET/SMARTZONE Scanning Failsoft OperationDynamic Regrouping Supervisory Tones Menu Description Keypad ProgrammingZone Change Parameter System Parameters Channel Change ParameterChannel Parameters Programming Setup Pctrunk Software InstallationTransceiver Programming Computer DescriptionConnecting RPI to Computer and Transceiver Starting and ExitingProgramming File Types Help FilesScreen Pop-Up Buttons and File Size Indicator Programming ProcedureFile Size Indication Creating and Displaying SystemsMenu Commands Menu BarRadio Type Menu Download Menu Upload MenuSystems Menu Window MenuDefaults RADIO-WIDE Parameter ScreensBand ZonesRadio Wide Scan List Radio-Wide Scan List ScreenModify List Screen Assign Function ButtonsRADIO-WIDE Conventional Screen RADIO-WIDE SMARTNET/SMARTZONE ScreenFull Spectrum CC Scan Hot DtmfAdjustable Parameters RADIO-WIDE Portable Options ScreenProgramming Conventional Systems and Channels Conventional System General ScreenTimers Conventional System Modify Scan List ScreenKeypad Editing Scan List ButtonSetting UP Conventional Channels Scan TimersPriority Channel Selection Conventional Channel Screen Parameters Selected ChannelTransmit Power SignalingChannel Type Tx Time-OutRestricted Access Time-Out TimerISW Delay Time Splinter ChannelsSMARTNET/SMARTZONE System Other ID’S Screen SMARTNET/SMARTZONE System Phone Interconnect ScreenPhone Interconnect Private CallSMARTNET/SMARTZONE System Emergency Settings Screen Emergency AlarmSMARTNET/SMARTZONE System Talk Groups Screen Failsoft ChannelTrunking Phone List Screen SMARTNET/SMARTZONE System Lists ScreensMessage Aliasing Screen Announcement Groups Screen Control Channels ScreenTrunking Call List Screen Status Aliasing Screen Setting UP SMARTNET/SMART- Zone ChannelsSMARTNET/SMARTZONE Channel Screen Parameters SMARTNET/SmartZone Channel Screen Other Screen ParametersCall Guard CTCSS/DCS Codes and Tones Recommended Tone Call Guard Codes FreqMHz Channels MHz Channels MHz Channels MHz Channels MHz Channels MHz Channels Power Switching and Regulation Power SwitchingCircuit Description Synthesizer DescriptionSynthesizer Chip IC1 VCO and Tcxo ModulationCharge Pump Q1, Q2, Loop Filter RF Amplifier Q1, First Mixer Q2 Receiver Circuit DescriptionIf Amplifier Q2, LIMITER/DETECTOR IC3 Antenna Switch and LOW-PASS Filter Squelch Circuit IC4A/B, IC5ATransmitter Description Amplifier Q9, Driver Q8Control Logic and Display Receive Audio ProcessingMicroprocessor IC306 Pin Descriptions Pin Port Name Input or Description Active High OutputHvfulswlrq Receive and Transmit Data Processing Audio Amplifier IC104-IC106Receive Data FILTER/DETECTOR IC102A/B, IC107A/B Transmit Data Filter IC206B/ IC206A Transmit Audio ProcessingLOW-PASS Filter IC205A/B Smartnet Data ProcessingBattery Pack and Charger Information Battery PackPower Setting Operating Time Function Fahrenheit CelsiusBattery Pack and Charger Information Alignment Procedure and Performance Tests Test SetupTune Software Hqhudo Mm/3/32 Mm/1/8 Phone JackPreliminary Setup Main Pctune ScreenTransmit Frequency and Power Transmit Power Adjustment ScreenHigh Power Level = 3.0 watts Low Power Level = 1.0 watt Modulation BalanceSquelch Adjust Rssi AdjustAudio Deviation Data DeviationPerformance Tests Receiver Performance TestsPower Output Transmitter Performance TestsTransmit Frequency Transmit ModulationThis page intentionally left blank Parts List Display AssemblyChassis Parts Ref No DescriptionKEY Assembly Display AssemblyKEY Assembly If AssemblyIf Assembly PLL Assembly RF UnitRF Unit NJM2904V-TE1 IC RF Unit Logic Unit Logic Unit TDA7233D IC Logic Unit 200K ERJ3GE MP35 MP18 MP25 KEY Front Panel EP2EP1 MP32 MP33 MP27 MP34 MP28 MP29 MP23 MP22 MP30 MP24 MP26 MP18 PLL Board TOP View Schematic Diagrams and Component LayoutsPLL Board Bottom View If Board TOP View If Board Bottom ViewTransceiver Block Diagram RF UnitRF Board TOP View MICRF Board Schematic If AMPLogic Board TOP View HD1Logic Board Schematic Receive Audio ProcessingDisplay Board Bottom View GND KEYR3 KEYR2 KEYR1 KEYR0 KEYS3 KEYS2 KEYS1 KEYS0 GNDDisplay Board Schematic DS3 DS4 DS5KEY Board Front View KEY Board Back ViewKEY Board Schematic S S R R R RScan HC2 HC7 HC8 HC3 Schematic Diagrams and Component Layouts