EFJohnson 7780 service manual Keypad Programming, Menu Description, Zone Change Parameter

Page 35

TRANSCEIVER OPERATION

Six Beeps

The paged radio received the page and acknowl- edged it (Section 2.5.7).

The message that was sent has been received and acknowledged (Section 2.5.8).

The status condition that was sent has been received and acknowledged (Section 2.5.9).

Two Beeps

The emergency alarm condition was acknowledged (Section 2.5.10).

Gurgle-Like Tone

Dynamic regrouping has occurred (Section 2.5.13).

Dynamic regrouping has occurred but the regrouping channel is not selected (Section 2.5.13).

Four Low Tones (Busy Signal)

The radio system is busy or a busy condition exists when making a telephone call.

Four Alternating High and Low Tones

A channel is available after a busy condition occurred (SMARTNET/SmartZone only).

2.7 KEYPAD PROGRAMMING

2.7.1 INTRODUCTION

NOTE: Keypad programming is available with full keypad (15-key) models only.

Keypad programming is available if the Keypad Programming option switch is programmed. It is then selected by simply pressing this switch (no password is required). Keypad programming allows conven- tional channel parameters such as the transmit and receive frequency and Call Guard squelch code to be changed. In addition, it allows several conventional mode timers to be changed. It cannot be used to repro- gram disabled channels or SMARTNET/SmartZone channels.

2.7.2 MENU DESCRIPTION

A menu is used to select parameters to be changed in the keypad programming mode. When the Keypad Programming mode is selected by pressing the option switch, the “ P” and “ G” icons are displayed (see Figure 2-3) along with the first menu parameter “ZONE CHG”.

The four main menu parameters are listed below, and descriptions are located in the indicated section.

Press the and keys to display the desired parameter and then press the ENT key to select it. Pressing the CLR key in any of the four main menus exits the keypad programming mode. Pressing it in the other menus returns to the previous menu. A flowchart showing the keypad programming mode menu struc- ture is located in Figure 2-4.

ZONE CHG (2.7.3)

CHAN CHG (2.7.4)

SYS PRM (2.7.5)

CHAN PRM (2.7.6)

Zone

Channel

System

Channel

Change

Change

Parameters

Parameters

Select

Select

Rx Freq

 

 

Zone

Channel

Tx Freq

Scan Hold Timer

Rx CG Code

Time-Out Timer

Tx CG Code

 

Penalty Timer

Tx Power

 

Conver. Timer

TOT On-Off

Figure 2-4 Keypad Programming Menu

Flowchart

2.7.3 ZONE CHANGE PARAMETER

The “ZONE CHG” menu parameter selects the zone containing the conventional channel to be repro- grammed. It does not change the zone selected for normal operation. Enter the zone number or scroll through the programmed zones by pressing the

and keys. When the desired zone is displayed, select it by pressing the ENT key.

 

November 1999

2-21

Part No. 001-7780-500

Image 35
Contents 7780 Page Page Table of Contents Table of Contents CONT’D List of Figures List of TablesScope of Manual Equipment Description General InformationTransceiver Identification AccessoriesFactory Customer Service Part Number BreakdownFactory Returns AccessoriesAccessory Toll-Free 800Definitions Replacement PartsInternet Home Intrinsically Safe Information Classification of Hazardous Areas and Atmospheres Temperature Code T3CPossible Ignition Sources Intrinsically Safe and Nonincendive RatingsArea Classification Accessing PC BoardsMaterial Classification Typical Hazard Group ClassRemoving Logic Unit Removing RF UnitGeneral SpecificationsControls and Display FeaturesTransceiver Operation Low-Battery Indicator Amber TX Indicator Red Indicates when the transmitter is keyedDisplay DisplayFront Panel Keys Full Keypad Model Backlight Turning Power on and Setting VolumeOption Switches General OperationSee Option Switch FunctionsFunction Conv Scanning Tone ENABLE/DISABLEConventional and SMARTNET/ Smartzone Operation Monitoring Before Transmitting Conventional FeaturesDisplay Mode Selection Call Guard Squelch Monitor ModeBusy Channel Lockout Conventional Mode Scanning Penalty TimerConversation Timer Power Output SelectPriority Channel Sampling Standard Conventional Calls DTMF/ANI SignalingEnhanced Private Conversation Calls SMARTNET/SMARTZONE FeaturesViewing Unit ID Standard Group CallsTransceiver Operation Private Conversation II Calls Telephone Calls Call Alert Sending Status Conditions Emergency Alarm and CallMessaging Dynamic Regrouping Failsoft OperationSMARTNET/SMARTZONE Scanning Supervisory Tones Zone Change Parameter Keypad ProgrammingMenu Description Channel Parameters Channel Change ParameterSystem Parameters Computer Description Programming SetupPctrunk Software Installation Transceiver ProgrammingHelp Files Connecting RPI to Computer and TransceiverStarting and Exiting Programming File TypesCreating and Displaying Systems Screen Pop-Up Buttons and File Size IndicatorProgramming Procedure File Size IndicationMenu Bar Menu CommandsWindow Menu Radio Type MenuDownload Menu Upload Menu Systems MenuZones DefaultsRADIO-WIDE Parameter Screens BandAssign Function Buttons Radio Wide Scan ListRadio-Wide Scan List Screen Modify List ScreenHot Dtmf RADIO-WIDE Conventional ScreenRADIO-WIDE SMARTNET/SMARTZONE Screen Full Spectrum CC ScanConventional System General Screen Adjustable ParametersRADIO-WIDE Portable Options Screen Programming Conventional Systems and ChannelsScan List Button TimersConventional System Modify Scan List Screen Keypad EditingPriority Channel Selection Scan TimersSetting UP Conventional Channels Selected Channel Conventional Channel Screen ParametersTx Time-Out Transmit PowerSignaling Channel TypeSplinter Channels Restricted AccessTime-Out Timer ISW Delay TimePrivate Call SMARTNET/SMARTZONE System Other ID’S ScreenSMARTNET/SMARTZONE System Phone Interconnect Screen Phone InterconnectFailsoft Channel SMARTNET/SMARTZONE System Emergency Settings ScreenEmergency Alarm SMARTNET/SMARTZONE System Talk Groups ScreenMessage Aliasing Screen SMARTNET/SMARTZONE System Lists ScreensTrunking Phone List Screen Control Channels Screen Announcement Groups ScreenTrunking Call List Screen SMARTNET/SMARTZONE Channel Screen Parameters Setting UP SMARTNET/SMART- Zone ChannelsStatus Aliasing Screen Other Screen Parameters SMARTNET/SmartZone Channel ScreenRecommended Tone Call Guard Codes Freq Call Guard CTCSS/DCS Codes and TonesMHz Channels MHz Channels MHz Channels MHz Channels MHz Channels MHz Channels Synthesizer Description Power Switching and RegulationPower Switching Circuit DescriptionCharge Pump Q1, Q2, Loop Filter VCO and Tcxo ModulationSynthesizer Chip IC1 If Amplifier Q2, LIMITER/DETECTOR IC3 Receiver Circuit DescriptionRF Amplifier Q1, First Mixer Q2 Amplifier Q9, Driver Q8 Antenna Switch and LOW-PASS FilterSquelch Circuit IC4A/B, IC5A Transmitter DescriptionReceive Audio Processing Control Logic and DisplayPin Port Name Input or Description Active High Output Microprocessor IC306 Pin DescriptionsHvfulswlrq Receive Data FILTER/DETECTOR IC102A/B, IC107A/B Audio Amplifier IC104-IC106Receive and Transmit Data Processing Transmit Audio Processing Transmit Data Filter IC206B/ IC206ASmartnet Data Processing LOW-PASS Filter IC205A/BFunction Fahrenheit Celsius Battery Pack and Charger InformationBattery Pack Power Setting Operating TimeBattery Pack and Charger Information Test Setup Alignment Procedure and Performance TestsMm/3/32 Mm/1/8 Phone Jack Tune Software HqhudoMain Pctune Screen Preliminary SetupModulation Balance Transmit Frequency and PowerTransmit Power Adjustment Screen High Power Level = 3.0 watts Low Power Level = 1.0 wattData Deviation Squelch AdjustRssi Adjust Audio DeviationReceiver Performance Tests Performance TestsTransmit Modulation Power OutputTransmitter Performance Tests Transmit FrequencyThis page intentionally left blank Ref No Description Parts ListDisplay Assembly Chassis PartsDisplay Assembly KEY AssemblyIf Assembly If AssemblyKEY Assembly RF Unit PLL AssemblyRF Unit NJM2904V-TE1 IC RF Unit Logic Unit Logic Unit TDA7233D IC Logic Unit 200K ERJ3GE MP35 MP18 MP25 EP2 KEY Front PanelEP1 MP32 MP33 MP27 MP34 MP28 MP29 MP23 MP22 MP30 MP24 MP26 MP18 PLL Board Bottom View Schematic Diagrams and Component LayoutsPLL Board TOP View If Board Bottom View If Board TOP ViewRF Unit Transceiver Block DiagramMIC RF Board TOP ViewIf AMP RF Board SchematicHD1 Logic Board TOP ViewReceive Audio Processing Logic Board SchematicGND KEYR3 KEYR2 KEYR1 KEYR0 KEYS3 KEYS2 KEYS1 KEYS0 GND Display Board Bottom ViewDS3 DS4 DS5 Display Board SchematicKEY Board Back View KEY Board Front ViewS S R R R R KEY Board SchematicScan HC2 HC7 HC8 HC3 Schematic Diagrams and Component Layouts