Page 30

TRANSCEIVER OPERATION

2.To answer the call, press the Private Call option switch and then the PTT switch and begin talking. The private call mode is indicated by “ C” in the upper part of the display. The alias of the incoming call is displayed if the ID is in your call list. Other- wise, the unit ID is displayed. NOTE: If the Private Call option switch is not pressed before the PTT switch, a group call is transmitted on the selected group.

To end the call when the conversation is complete or at any other time, press the CLR key. If the call is not answered within 20 seconds, it is automati- cally terminated.

If private calls are not permitted (Private Call switch not programmed), press the Call Response option switch, if available, to answer the call.

2.5.6 TELEPHONE CALLS

General

Telephone calls allow calls to be placed and received over the public telephone system using the transceiver. If the transceiver is programmed for tele- phone calls (Phone option switch programmed), they are placed and received as follows:

Placing a Telephone Call

Telephone calls can be placed by selecting the number from a preprogrammed phone number list (list entry) or by directly entering it using the keypad (direct entry). Direct entry is available with full keypad (15-key) models only. Proceed as follows:

List Entry Method (All Models)

1.With a SMARTNET/SmartZone channel selected, momentarily press the Phone option switch. The

phone mode is indicated by the icon, and the display indicates the alias of the last called tele-

phone number if it is in your phone number list. Otherwise, the last called telephone number is displayed.

2.Enter the index of the desired telephone number if

you know it or scroll through the list using the

and keys until you find the desired number. Press the CLR key to cancel the call.

3.Press the PTT switch or the ENT key to initiate the call. The display indicates “WAIT” while the connection to the phone system is occurring. Once connected, the normal dial tone is heard and the alias of the number being called is displayed. The radio then automatically dials the telephone number and the normal ringing or busy tone is heard. Proceed to the bulleted list which follows the next method for conditions that may then occur.

Direct Entry Method (Full Keypad Models Only)

1.With a SMARTNET/SmartZone channel selected, press and hold the Phone option switch until a tone sounds (approximately 1 second). The last phone number called is displayed, and the phone mode is

indicated by the icon.

2.Enter the number using the 0-9and # keys. To dial

a * character, press F1 and then the * key. To enter a pause (indicated by “P”), press the F1, *, and then # keys. The number scrolls to the left in the

display so that the seven right-most digits are always displayed. Numbers up to 16 digits (including pauses) can be entered. Press the CLR key to cancel the call.

3.Press the PTT switch or the ENT key to initiate the call. The display indicates “WAIT” while the connection to the phone system is occurring. Once connected, the normal dial tone is heard and the alias of the number being called is displayed. The radio then automatically dials the telephone number and the normal ringing or busy tone is heard. Any of the following conditions may then occur.

After the called party answers, press the PTT switch to talk and release it to listen. You cannot talk and listen at the same time because the radio cannot transmit and receive at the same time. Each time the PTT switch is released, a tone is heard by the other party that indicates when a response can be made. To end the call when the conversation is complete or at any other time, press the CLR key.

If enabled by dealer programming, a number can be dialed during a call by simply holding down the PTT switch and dialing the number.

November 1999

 

Part No. 001-7780-500

2-16

Image 30
Contents 7780 Page Page Table of Contents Table of Contents CONT’D List of Tables List of FiguresGeneral Information Scope of Manual Equipment DescriptionPart Number Breakdown AccessoriesFactory Customer Service Transceiver IdentificationToll-Free 800 AccessoriesAccessory Factory ReturnsReplacement Parts Internet Home Intrinsically Safe InformationDefinitions Intrinsically Safe and Nonincendive Ratings Temperature Code T3CPossible Ignition Sources Classification of Hazardous Areas and AtmospheresTypical Hazard Group Class Accessing PC BoardsMaterial Classification Area ClassificationRemoving RF Unit Removing Logic UnitSpecifications GeneralFeatures Transceiver OperationControls and Display TX Indicator Red Indicates when the transmitter is keyed Low-Battery Indicator AmberDisplay Front Panel Keys Full Keypad ModelDisplay General Operation Turning Power on and Setting VolumeOption Switches BacklightOption Switch Functions Function ConvSee Tone ENABLE/DISABLE ScanningConventional and SMARTNET/ Smartzone Operation Conventional Features Display Mode SelectionMonitoring Before Transmitting Monitor Mode Busy Channel LockoutCall Guard Squelch Power Output Select Penalty TimerConversation Timer Conventional Mode ScanningPriority Channel Sampling DTMF/ANI Signaling Standard Conventional CallsStandard Group Calls SMARTNET/SMARTZONE FeaturesViewing Unit ID Enhanced Private Conversation CallsTransceiver Operation Private Conversation II Calls Telephone Calls Call Alert Emergency Alarm and Call MessagingSending Status Conditions Failsoft Operation SMARTNET/SMARTZONE ScanningDynamic Regrouping Supervisory Tones Keypad Programming Menu DescriptionZone Change Parameter Channel Change Parameter System ParametersChannel Parameters Transceiver Programming Programming SetupPctrunk Software Installation Computer DescriptionProgramming File Types Connecting RPI to Computer and TransceiverStarting and Exiting Help FilesFile Size Indication Screen Pop-Up Buttons and File Size IndicatorProgramming Procedure Creating and Displaying SystemsMenu Commands Menu BarSystems Menu Radio Type MenuDownload Menu Upload Menu Window MenuBand DefaultsRADIO-WIDE Parameter Screens ZonesModify List Screen Radio Wide Scan ListRadio-Wide Scan List Screen Assign Function ButtonsFull Spectrum CC Scan RADIO-WIDE Conventional ScreenRADIO-WIDE SMARTNET/SMARTZONE Screen Hot DtmfProgramming Conventional Systems and Channels Adjustable ParametersRADIO-WIDE Portable Options Screen Conventional System General ScreenKeypad Editing TimersConventional System Modify Scan List Screen Scan List ButtonScan Timers Setting UP Conventional ChannelsPriority Channel Selection Conventional Channel Screen Parameters Selected ChannelChannel Type Transmit PowerSignaling Tx Time-OutISW Delay Time Restricted AccessTime-Out Timer Splinter ChannelsPhone Interconnect SMARTNET/SMARTZONE System Other ID’S ScreenSMARTNET/SMARTZONE System Phone Interconnect Screen Private CallSMARTNET/SMARTZONE System Talk Groups Screen SMARTNET/SMARTZONE System Emergency Settings ScreenEmergency Alarm Failsoft ChannelSMARTNET/SMARTZONE System Lists Screens Trunking Phone List ScreenMessage Aliasing Screen Announcement Groups Screen Control Channels ScreenTrunking Call List Screen Setting UP SMARTNET/SMART- Zone Channels Status Aliasing ScreenSMARTNET/SMARTZONE Channel Screen Parameters SMARTNET/SmartZone Channel Screen Other Screen ParametersCall Guard CTCSS/DCS Codes and Tones Recommended Tone Call Guard Codes FreqMHz Channels MHz Channels MHz Channels MHz Channels MHz Channels MHz Channels Circuit Description Power Switching and RegulationPower Switching Synthesizer DescriptionVCO and Tcxo Modulation Synthesizer Chip IC1Charge Pump Q1, Q2, Loop Filter Receiver Circuit Description RF Amplifier Q1, First Mixer Q2If Amplifier Q2, LIMITER/DETECTOR IC3 Transmitter Description Antenna Switch and LOW-PASS FilterSquelch Circuit IC4A/B, IC5A Amplifier Q9, Driver Q8Control Logic and Display Receive Audio ProcessingMicroprocessor IC306 Pin Descriptions Pin Port Name Input or Description Active High OutputHvfulswlrq Audio Amplifier IC104-IC106 Receive and Transmit Data ProcessingReceive Data FILTER/DETECTOR IC102A/B, IC107A/B Transmit Data Filter IC206B/ IC206A Transmit Audio ProcessingLOW-PASS Filter IC205A/B Smartnet Data ProcessingPower Setting Operating Time Battery Pack and Charger InformationBattery Pack Function Fahrenheit CelsiusBattery Pack and Charger Information Alignment Procedure and Performance Tests Test SetupTune Software Hqhudo Mm/3/32 Mm/1/8 Phone JackPreliminary Setup Main Pctune ScreenHigh Power Level = 3.0 watts Low Power Level = 1.0 watt Transmit Frequency and PowerTransmit Power Adjustment Screen Modulation BalanceAudio Deviation Squelch AdjustRssi Adjust Data DeviationPerformance Tests Receiver Performance TestsTransmit Frequency Power OutputTransmitter Performance Tests Transmit ModulationThis page intentionally left blank Chassis Parts Parts ListDisplay Assembly Ref No DescriptionKEY Assembly Display AssemblyIf Assembly KEY AssemblyIf Assembly PLL Assembly RF UnitRF Unit NJM2904V-TE1 IC RF Unit Logic Unit Logic Unit TDA7233D IC Logic Unit 200K ERJ3GE MP35 MP18 MP25 KEY Front Panel EP2EP1 MP32 MP33 MP27 MP34 MP28 MP29 MP23 MP22 MP30 MP24 MP26 MP18 Schematic Diagrams and Component Layouts PLL Board TOP ViewPLL Board Bottom View If Board TOP View If Board Bottom ViewTransceiver Block Diagram RF UnitRF Board TOP View MICRF Board Schematic If AMPLogic Board TOP View HD1Logic Board Schematic Receive Audio ProcessingDisplay Board Bottom View GND KEYR3 KEYR2 KEYR1 KEYR0 KEYS3 KEYS2 KEYS1 KEYS0 GNDDisplay Board Schematic DS3 DS4 DS5KEY Board Front View KEY Board Back ViewKEY Board Schematic S S R R R RScan HC2 HC7 HC8 HC3 Schematic Diagrams and Component Layouts