Heat Controller DMC24CA-1 manual Forced Operation, Auto Restart Function, Tips for Filter sign LED

Page 22

Operating Instructions

ForcedOperation

Operation procedures when the remote control can't be used. Press the tact switch (Forced operation) for 2 seconds.

If you want to stop operation, press again the tact switch.

In case the power comes on again after power failure on the Forced Operation mode, the operating conditions are automatically set as follows:

During Forced Operation, the initial mode continues.

Forced operation (Tact switch)

 

Cooling Model

Heat pump Model

 

 

 

 

Room Temp. set Temp.-2°C

Room Temp. < set Temp.-2°C

 

 

Operating mode

Cooling

Cooling

Heating

 

 

 

 

Indoor FAN Speed

High

set available

set available

 

 

 

 

Setting Temperature

22°C

set available

set available

 

 

 

 

Auto RestartFunction

In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions.

TipsforFiltersignLED

1Filter sign lamp (LED) is ON.

2If LED indicating filter sign lamp is ON, clean the filter.

3After cleaning the filter, press the Timer button and button of wired remote controller at the same time for 3 sec. Then filter sign LED is OFF.

PLASMAPurificationOperation

AUTO SWING

OPERATION

SET TEMP

FAN SPEED

SUB FUNCTION

 

 

 

Room Temp

HI

AUTO

Heater

Preheat

 

 

 

 

 

 

 

 

MED

JET

Defrost

Humidify

 

 

 

 

LO

 

Filter

Out door

 

 

 

Time

ZONE

 

1 2 3 4

Timer

Operation unit

Program set

 

 

 

 

On Off

 

 

 

 

 

 

 

Set no. Time

01

03 05 07

09 11 13

15 17

19

21

23

Timer Cancel 2ndF

Program Week Holiday

Plasma

Set/Clr

Hour Min

RESET

1 Press the On/Off button. The unit will respond with a beep.

2 Open the door on the remote control. Press the

Plasma

PLASMA air purifying operation ON/OFF button. Operation will start when the button is pressed and stop when the button is pressed again.

3 Set the fan speed again with door of the remote control closed. You can select the fan speed in four steps-low, medium, high or Auto. Each time the button is pressed, the fan speed

mode is shifted.

22Cassette- Type Air Conditioner

Image 22
Contents Heat CONTROLLER, INC Important InformationTable of Contents There is risk of fire or electric shock Always ground the productDo not modify or extend the power cable Do not place anything on the power cableDo not allow water to run into electric parts Away properly Bad connection may cause Install the drain hose toEnsure that water is drained Water leakage LeakageDo not block the inlet or outlet of air flow Cassette Type Indoor Unit Signal ReceiverIndoor Unit On/Off Lights up during the system operation Filter SignName and Function of Remote Controller Signal transmitter Wireless Remote ControllerWireless remote controller do not operate the swirl mode Set the Current Time and day of the Week MinPress the Program button Press button repeatedly until desired mode appearsWeekly Programming If you press SET/CLR button, thenTimer Setting Holiday SettingSelf-diagnosis Function Operation Mode Cooling Operation Mode Set the temperature lower than the room temperatureCooling Operation Soft Dry Operation ModeAuto Operation Temperature can be set within a range of -2~2 by 1 level Auto Operation ModeTo raise the Temperature To lower the Temperature FAN Operation Mode Press the On/Off Button Press FAN Operation ButtonComfort Operation with Swirl Press the On/Off Button. The unit will respond with a beepVane Control Child Lock Function Auto Swing ModeFan speed and cooling capacity Tips for Filter sign LED Forced OperationAuto Restart Function Plasma Purification OperationRemove the Air filters Cleaner or washing with waterInstall the air filter After washing with water, dry well in the shadePurifying filter Recomended use period About 2 yearsOperation Tips Troubleshooting Heat CONTROLLER, INC