Heat Controller DMC24CA-1, DMC36CA-1 manual Purifying filter, Recomended use period About 2 years

Page 24

Maintenance and Service

Purifyingfilter

Cleaning

The PLASMA filter behind the air filters should be checked and cleaned once every 3 months or more often if necessary.

Replacement

Recomended use period : About 2 years

1Open front panel and remove air filter.

1After removing the air filters, pull slightly forward to remove the PLASMA filter.

2Dip the PLASMA filter into the water mixed with neutral detergent, for 20~30 minutes.

3Dry the PLASMA filter in the shade for a day (Especially, the humidity must be removed perfectly on this parts).

4Note the cuts of electric discharge lines.

5Re-install the PLASMA filter to the original position.

CAUTION:Don’t touch this PLASMA Filter within 10 seconds after opening the inlet grille, it may cause an electric shock.

4Reinsert air filter and close front panel.

2 Remove air purifying filter.

3 Insert new air purifying filter.

2

1

24Cassette- Type Air Conditioner

Image 24
Contents Heat CONTROLLER, INC Important InformationTable of Contents There is risk of fire or electric shock Always ground the productDo not modify or extend the power cable Do not place anything on the power cableDo not allow water to run into electric parts Install the drain hose to Ensure that water is drainedAway properly Bad connection may cause Water leakage LeakageDo not block the inlet or outlet of air flow Signal Receiver Indoor UnitCassette Type Indoor Unit On/Off Lights up during the system operation Filter SignName and Function of Remote Controller Wireless Remote Controller Signal transmitterWireless remote controller do not operate the swirl mode Set the Current Time and day of the Week MinPress button repeatedly until desired mode appears Weekly ProgrammingPress the Program button If you press SET/CLR button, thenHoliday Setting Timer SettingSelf-diagnosis Function Operation Mode Cooling Operation Mode Set the temperature lower than the room temperatureSoft Dry Operation Mode Cooling OperationAuto Operation Auto Operation Mode Temperature can be set within a range of -2~2 by 1 levelTo raise the Temperature To lower the Temperature FAN Operation Mode Press the On/Off Button Press FAN Operation ButtonComfort Operation with Swirl Press the On/Off Button. The unit will respond with a beepVane Control Auto Swing Mode Child Lock FunctionFan speed and cooling capacity Forced Operation Auto Restart FunctionTips for Filter sign LED Plasma Purification OperationCleaner or washing with water Install the air filterRemove the Air filters After washing with water, dry well in the shadePurifying filter Recomended use period About 2 yearsOperation Tips Troubleshooting Heat CONTROLLER, INC
Related manuals