Samsung FQV313T004/BOL manual Error codes, Error code General functions

Models: FQV313T004/BOL

1 336
Download 336 pages 51.91 Kb
Page 333
Image 333

error codes

Error codes

Error code

General functions

TEMP SENSOR OPEN

In case the value of the temperature sensor is more than 250 °C during operation / cancellation.

TEMP SENSOR SHORT

In case the value of the temperature sensor is less than 5 °C during operation / cancellation.

UNFINISHED PREHEAT

In case the oven has not reached the desired temperature although a certain amount of time has passed (unfinished preheating).

OVER 250 °C DURING OPERATION OF CONVECTION

In case the temperature rises over 250 °C during operation of convection mode.

STEAM SENSOR OPEN

In case the value of the temperature sensor is less than 30 °C after operation of the steam heater for a certain time.

STEAM SENSOR SHORT

DESCALE MAX. TIME OVER (or STEAM USE MAX TIME OVER) In case the steam operating time after the descaling message has been passed.

If any of these errors occur, please contact SAMSUNG Customer Service.

s de co rror05 e

error codes _53

FQV313T004_BOL-03643P_EN.indb 53

2010-07-30 �� 6:07:47

Page 333
Image 333
Samsung FQV313T004/BOL manual Error codes, Error code General functions