error codes

Error codes

Error code

General functions

TEMP SENSOR OPEN

In case the value of the temperature sensor is more than 250 °C during operation / cancellation.

TEMP SENSOR SHORT

In case the value of the temperature sensor is less than 5 °C during operation / cancellation.

UNFINISHED PREHEAT

In case the oven has not reached the desired temperature although a certain amount of time has passed (unfinished preheating).

OVER 250 °C DURING OPERATION OF CONVECTION

In case the temperature rises over 250 °C during operation of convection mode.

STEAM SENSOR OPEN

In case the value of the temperature sensor is less than 30 °C after operation of the steam heater for a certain time.

STEAM SENSOR SHORT

DESCALE MAX. TIME OVER (or STEAM USE MAX TIME OVER) In case the steam operating time after the descaling message has been passed.