Installation

HowtoInstall

Window Requirements

INNER

 

SILL

NOTICE All supporting parts should be secured to firm wood, masonry, or metal.

1.This unit is designed for installation in standard double hung windows with actual opening widths of 22" to 36". The upper and lower sash must open sufficiently to allow a clear vertical opening of 15" from the bottom of the sash to the window stool.

2.If storm window presents interference, fasten a 2" wide wood strip to the inner window sill across the full width of the sill. The wood strip should be thick enough to raise the height of the window sill so that the unit can be installed without interference by the storm window frame. See Figure. 4. Top of wood strip should be approximately 3/4" higher than the storm window frame (STORM WINDOW FRAME) or wood strip (OUT- DOORS) to help condensation to drain properly to the outside.

3.Install a second wood strip (approximately 6" long by 11/2" wide and same thickness as first strip) in the center of the outer sill flush against the back off the inner sill. This will raise the L bracket as shown Figure. 4.

4.If the distance between STORM WINDOW FRAME and WOOD STRIP MOUNTED ON TOP OF INNER SILL is more than 1", two of wood strip are not necessary.

 

OUTER

 

SILL

INDOORS

OUTDOORS

 

Figure 3

WOOD STRIP MOUNTED

1" MAX.

ON TOP OF INNER SILL

3/4"

 

CLEARANCE

 

STORM

INNER

WINDOW

FRAME

SILL

 

WOOD STRIP

FOR L BRACKET

 

OUTER

 

SILL

INDOORS

OUTDOORS

Figure 4

Installation

HARDWARE

Type A:16EA

Type B:3EA

Type C:5EA

Type H:1EA

Type I:1EA

Type J:1EA

Type K:2EA

(SCREW)

(SCREW)

(SCREW)

(FOAM-STRIP)

(UPPER GUIDE)

(FOAM-PE)

(FRAME-GUIDE)

10mm

16mm

16mm

Type D:2EA

(NUT)

Type E:2EA

(FRAME CURTAIN)

Type F:2EA

(SILL SUPPORT)

Type G:2EA

(BOLT)

Type L:1EA

(WINDOWLOCKINGBRACKET)

Type M:1EA (FOAM-PE)

Type N:1EA

(DRAIN JOINT PIPE)

Type O:1EA

(DRAIN WASHER)

10

Service Manual 11

Image 11
Contents +$7&21752//5,1& Table of Contents Do not disassemble or modify products Safety PrecautionsAlways install the expansion panels Do not use the socket if it is loose or damaged Plug in the power plug properlyDo not modify power cord length Ventilate before operating air conditionerwhen gas goes outDo not clean the air conditioner with water Outside Dimensions DimensionsSymbols Used in this Manual Items Product SpecificationsRAD 81A Rads 81B Select the Best Location InstallationInstallation Check How to Secure the Drain PipeWindow Requirements How to InstallPreparation of Chassis Cabinet InstallationIndoor Outdoor Window Locking Bracket For Maximum Cooling OperationLocation and Function of Controls For Normal CoolingRemote Control Operations Cabinet DisassemblyMechanical Parts Front GrilleFAN and Shroud Air Handling PartsAIR Guide and Blower Compressor Electrical PartsMotor Overload ProtectorThermostat Model Rotary Switch Type Model Capacitor Model Rotary Switch Type ModelModel Touch & Remote Control Type Model Condenser Rotary Switch Model Rotary Switch Type ModelPower Cord Refrigerating CycleCapillary Tube EvaporatorPulling Vacuum Wiring Diagram Schematic DiagramCircuit Diagram Electronic Control Device Components LocationFor Main P.W.B ASM Piping System Troubleshooting GuideUnit runs but poor cooling Troubleshooting GuideFails to Start Possible Trouble Electric Parts Troubleshooting GuideModel BG8000ER, WG8000RY4, WG1000RY4 Set the Temp. setting to lower Temp Is the voltage No.16 Room AIR Conditioner Voltage Limits Troubleshooting Guide Troubleshooting Guide W0CZZ Exploded Vie wReplacement Parts List +$7&21752//5,1&