Heat Controller RAD-81A, RAD-101A manual Electrical Parts, Motor, Overload Protector, Compressor

Page 19

Disassembly

3. MOTOR

1.

Remove the cabinet.

 

2.

Remove the evaporator.

 

3.

Remove the orifice.

 

4.

Remove the blower.

 

5.

Remove the fan.

 

6.

Remove the control box cover and housing of the

 

 

motor in the control box.

 

7.

Remove the 2 screws which fasten the motor from

 

 

the mount motor. (See Figure 23)

 

8.

Remove the motor.

 

9.

Re-install the components by referring to the

Figure 23

 

removal procedure, above.(See Figure 23)

ElectricalParts

1. OVERLOAD PROTECTOR

1. Remove the cabinet.

2. Remove the nut which fastens the terminal cover.

3. Remove the terminal cover. (See Figure 24)

4. Remove all the leads from the overload protector.

5. Remove the overload protector.

6. Re-install the component by referring to the removal procedure, above.

Figure 24

2.COMPRESSOR

1.Remove the cabinet.

2.Discharge the refrigerant system using a FreonTM

 

Recovery System.

 

 

If there is no valve to attach the recovery system,

 

 

install one (such as a WATCO A-1) before venting

 

 

the FreonTM. Leave the valve in place after

 

 

servicing the system.

 

3.

Remove the overload protector.

 

4.

After purging the unit completely, unbraze the

 

 

suction and discharge tubes at the compressor

 

 

connections.

 

5.

Remove the 3 nuts and the 3 washers which

 

 

fasten the compressor.

 

6.

Remove the compressor. (See Figure 25)

Figure 25

7.Re-install the components by referring to the removal procedure, above.

Service Manual 19

Image 19
Contents +$7&21752//5,1& Table of Contents Always install the expansion panels Safety PrecautionsDo not disassemble or modify products Do not use the socket if it is loose or damaged Plug in the power plug properlyDo not modify power cord length Ventilate before operating air conditionerwhen gas goes outDo not clean the air conditioner with water Symbols Used in this Manual DimensionsOutside Dimensions Items Product SpecificationsRAD 81A Rads 81B Select the Best Location InstallationInstallation Check How to Secure the Drain PipeWindow Requirements How to InstallPreparation of Chassis Cabinet InstallationIndoor Outdoor Window Locking Bracket For Maximum Cooling OperationLocation and Function of Controls For Normal CoolingRemote Control Operations Cabinet DisassemblyMechanical Parts Front GrilleAIR Guide and Blower Air Handling PartsFAN and Shroud Compressor Electrical PartsMotor Overload ProtectorModel Touch & Remote Control Type Model Capacitor Model Rotary Switch Type ModelThermostat Model Rotary Switch Type Model Condenser Rotary Switch Model Rotary Switch Type ModelPower Cord Refrigerating CycleCapillary Tube EvaporatorPulling Vacuum Wiring Diagram Schematic DiagramCircuit Diagram Electronic Control Device Components LocationFor Main P.W.B ASM Piping System Troubleshooting GuideUnit runs but poor cooling Troubleshooting GuideFails to Start Model BG8000ER, WG8000RY4, WG1000RY4 Electric Parts Troubleshooting GuidePossible Trouble Set the Temp. setting to lower Temp Is the voltage No.16 Room AIR Conditioner Voltage Limits Troubleshooting Guide Troubleshooting Guide W0CZZ Exploded Vie wReplacement Parts List +$7&21752//5,1&