Heat Controller RAD-101A manual Refrigerating Cycle, Rotary Switch Model Rotary Switch Type Model

Page 21

Disassembly

6. ROTARY SWITCH

MODEL : ROTARY SWITCH TYPE MODEL

1. Remove the control box.

2. Open the control box.

3. Remove the 2 screws which fasten the rotary switch.

4. Disconnect all the leads of the rotary switch terminals.

5. Remove the rotary switch.

 

6. Re-install the components by referring to the

above

removal procedure. (See Figure 29)

 

7. POWER CORD

Figure 29

1.Remove the control box.

2.Open the control box.

3.Disconnect the grounding screw from the control box.

4.Disconnect the 2 receptacles.

5.Remove a screw which fastens the clip cord.

(See Figure 30)

6. Remove the power cord.

 

7. Re-install the component by referring to the above

 

removal procedure, above.

 

(Use only one ground-marked hole for ground

 

connection.)

 

8. If the supply cord of this appliance is damaged, it

Figure 30

must be replaced by the special cord. (The

 

special cord means the cord which has the same

 

specification marked on the supply cord attached at

 

the unit.)

 

Refrigerating Cycle

CAUTION: Discharge the refrigerant system using a FreonTM Recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM. Leave the valve in place after servicing the system.

1.CONDENSER

1.Remove the cabinet.

2.Remove the 3 screws which fasten the

brace.

3. Remove the 3 screws which fasten the condenser and shroud.

4. After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections.

5. Remove the condenser carefully.

6. Re-install the component by referring to notes. (See Figure 31)

Figure 31

Service Manual 21

Image 21
Contents +$7&21752//5,1& Table of Contents Safety Precautions Always install the expansion panelsDo not disassemble or modify products Do not modify power cord length Plug in the power plug properlyVentilate before operating air conditionerwhen gas goes out Do not use the socket if it is loose or damagedDo not clean the air conditioner with water Dimensions Symbols Used in this ManualOutside Dimensions Items Product SpecificationsRAD 81A Rads 81B Installation Check InstallationHow to Secure the Drain Pipe Select the Best LocationWindow Requirements How to InstallPreparation of Chassis Cabinet InstallationIndoor Outdoor Window Locking Bracket Location and Function of Controls OperationFor Normal Cooling For Maximum CoolingRemote Control Operations Mechanical Parts DisassemblyFront Grille CabinetAir Handling Parts AIR Guide and BlowerFAN and Shroud Motor Electrical PartsOverload Protector CompressorCapacitor Model Rotary Switch Type Model Model Touch & Remote Control Type ModelThermostat Model Rotary Switch Type Model Power Cord Rotary Switch Model Rotary Switch Type ModelRefrigerating Cycle CondenserCapillary Tube EvaporatorPulling Vacuum Wiring Diagram Schematic DiagramCircuit Diagram Electronic Control Device Components LocationFor Main P.W.B ASM Piping System Troubleshooting GuideUnit runs but poor cooling Troubleshooting GuideFails to Start Electric Parts Troubleshooting Guide Model BG8000ER, WG8000RY4, WG1000RY4Possible Trouble Set the Temp. setting to lower Temp Is the voltage No.16 Room AIR Conditioner Voltage Limits Troubleshooting Guide Troubleshooting Guide W0CZZ Exploded Vie wReplacement Parts List +$7&21752//5,1&