Heat Controller RAD-81A, RAD-101A, RADS-81B Model BG8000ER, WG8000RY4, WG1000RY4, Possible Trouble

Page 31

Troubleshooting Guide

MODEL : BG8000ER, WG8000RY4, WG1000RY4

ELECTRIC PARTS TROUBLESHOOTING GUIDE:

Possible Trouble 1

Is the Trans input power AC 115V?

YES

Is the Trans output power

about AC 14V?

YES

Is output Voltage of IC01D

DC 12V?

YES

Is output Voltage of IC02D

DC 5V?

YES

• The unit does not operate.

NO

 

• Check the Fuse.

 

 

 

 

 

 

• Check the wiring diagram.

 

 

 

 

 

 

 

 

 

 

 

NO

 

NO

 

• Check the Main

 

 

 

 

 

Is shorted the Trans. output?

 

 

P.W.B pattern.

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Exchange the Trans.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

Exchange D02D~D05D.

 

 

 

 

 

 

 

• Exchange IC01D.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

• Exchange IC02D.

 

Is the reset circuit all right?

(The No.14 of Micom

is 5V.)

YES

Is the

connection between

Main and Display

all right?

YES

NO

NO

• Exchange IC01A.

Connect connector exactly.

Is the voltage No.18 of Micom

NO

 

• Check the P.W.B

 

 

 

 

 

 

pattern.

 

 

 

 

DC 5V?

 

 

 

 

 

 

 

 

 

YES

Exchange Main P.W.B Ass'y.

Service Manual 31

Image 31
Contents +$7&21752//5,1& Table of Contents Always install the expansion panels Safety PrecautionsDo not disassemble or modify products Do not use the socket if it is loose or damaged Plug in the power plug properlyDo not modify power cord length Ventilate before operating air conditionerwhen gas goes outDo not clean the air conditioner with water Symbols Used in this Manual DimensionsOutside Dimensions Items Product SpecificationsRAD 81A Rads 81B Select the Best Location InstallationInstallation Check How to Secure the Drain PipeWindow Requirements How to InstallPreparation of Chassis Cabinet InstallationIndoor Outdoor Window Locking Bracket For Maximum Cooling OperationLocation and Function of Controls For Normal CoolingRemote Control Operations Cabinet DisassemblyMechanical Parts Front GrilleAIR Guide and Blower Air Handling PartsFAN and Shroud Compressor Electrical PartsMotor Overload ProtectorModel Touch & Remote Control Type Model Capacitor Model Rotary Switch Type ModelThermostat Model Rotary Switch Type Model Condenser Rotary Switch Model Rotary Switch Type ModelPower Cord Refrigerating CycleCapillary Tube EvaporatorPulling Vacuum Wiring Diagram Schematic DiagramCircuit Diagram Electronic Control Device Components LocationFor Main P.W.B ASM Piping System Troubleshooting GuideUnit runs but poor cooling Troubleshooting GuideFails to Start Model BG8000ER, WG8000RY4, WG1000RY4 Electric Parts Troubleshooting GuidePossible Trouble Set the Temp. setting to lower Temp Is the voltage No.16 Room AIR Conditioner Voltage Limits Troubleshooting Guide Troubleshooting Guide W0CZZ Exploded Vie wReplacement Parts List +$7&21752//5,1&