Heat Controller RAD-81A, RAD-101A, RADS-81B manual Room AIR Conditioner Voltage Limits

Page 34

Troubleshooting Guide

ROOM AIR CONDITIONER VOLTAGE LIMITS

NAME PLATE RATING

MINIMUM

MAXIMUM

 

 

 

115V ± 10%

103.5V

126.5V

 

 

 

COMPLAINT

CAUSE

REMEDY

 

 

 

 

Fan motor will not run.

No power

Check voltage at outlet. Correct if none.

 

 

 

 

 

Power supply cord

Check voltage to rotary switch. If none, check

 

 

power supply cord. Replace cord if circuit is

 

 

open.

 

 

 

 

 

Rotary switch

Check switch continuity. Refer to wiring diagram

 

 

for terminal identification. Replace switch if

 

 

defective.

 

 

 

 

 

Wire disconnected or

Connect wire. Refer to wiring diagram for

 

connection loose

terminal identification. Repair or replace loose

 

 

terminal.

 

 

 

 

 

Capacitor (Discharge

Test capacitor.

 

capacitor before testing.)

Replace if not within ±10% of manufacturer's

 

 

rating. Replace if shorted, open, or damaged.

 

 

 

 

 

Will not rotate

Fan blade hitting shroud or blower wheel hitting

 

 

scroll. Re-align assembly.

 

 

Units using slinger ring condenser fans must

 

 

have 0.22~0.25 inch clearance to the base.

 

 

If necessary, shim up the bottom of the fan motor

 

 

with mounting screw(s).

 

 

Check fan motor bearings; if motor shaft will not

 

 

rotate, replace the motor.

 

 

 

 

Fan motor runs.

Revolves on overload

Check voltage. See limits on this page.

 

 

If not within limits, call an electrician.

 

 

Test capacitor.

 

 

Check bearings. Does the fan blade rotate

 

 

freely?

 

 

If not, replace fan motor.

 

 

Pay attention to any change from high speed to

 

 

low speed. If the speed does not change,

 

 

replace the motor.

 

 

 

 

34Room Air Conditioner

Image 34
Contents +$7&21752//5,1& Table of Contents Always install the expansion panels Safety PrecautionsDo not disassemble or modify products Ventilate before operating air conditionerwhen gas goes out Plug in the power plug properlyDo not modify power cord length Do not use the socket if it is loose or damagedDo not clean the air conditioner with water Symbols Used in this Manual DimensionsOutside Dimensions Product Specifications ItemsRAD 81A Rads 81B How to Secure the Drain Pipe InstallationInstallation Check Select the Best LocationHow to Install Window RequirementsCabinet Installation Preparation of ChassisIndoor Outdoor Window Locking Bracket For Normal Cooling OperationLocation and Function of Controls For Maximum CoolingRemote Control Operations Front Grille DisassemblyMechanical Parts CabinetAIR Guide and Blower Air Handling PartsFAN and Shroud Overload Protector Electrical PartsMotor CompressorModel Touch & Remote Control Type Model Capacitor Model Rotary Switch Type ModelThermostat Model Rotary Switch Type Model Refrigerating Cycle Rotary Switch Model Rotary Switch Type ModelPower Cord CondenserEvaporator Capillary TubePulling Vacuum Schematic Diagram Wiring DiagramCircuit Diagram Electronic Control Device Components LocationFor Main P.W.B ASM Troubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Model BG8000ER, WG8000RY4, WG1000RY4 Electric Parts Troubleshooting GuidePossible Trouble Set the Temp. setting to lower Temp Is the voltage No.16 Room AIR Conditioner Voltage Limits Troubleshooting Guide Troubleshooting Guide Exploded Vie w W0CZZReplacement Parts List +$7&21752//5,1&