into the HPMACRO command.

Download overlay as a HP-macro (HPMACRO)

Type choices, press Enter.

InterForm

400 file set .

. . . . KARTSET

______

Character value

Overlay name

. . . . KLICHE

______

Character value

Printer type

. . . . PRTTYP

______

IBM4019, IBM4029, IBM4039...

Interface

. . . . . . .

. . . . INTERF

______

SYSTEM, SYSTEM850, ASCIIR8...

Macro-id (0 32767) . . .

. . . . MACROID

______

0-32767

Automatic on every page

. . . . AUTOMATIC

______

*NO *YES

Place into Flash Memory

. . . . FLASHMEM

______

*NO *HP4 *IBM4039

Output queue

. . . . OUTQ

______

Name, *JOB

Library

. . . . . . .

. . . .

_______

Name, *LIBL

Form type

. . . . . . .

. . . . FORMTYPE

______

Character value

Bottom

F3=Exit F4=Prompt F5=Refresh F12=Cancel F13=How to use this display F24=More keys

KARTSET:

Defines the name of the file-set, in which you have defined the

 

overlay you wish to download as an HP macro.

KLICHE:

Is the name of the overlay you wish to download.

PRTTYP:

States the printer type you wish to use. If you are using another

 

printer type than the ones listed in PRTTYP you should select

 

HPII. Refer to page 374 for further information on the printer

 

types.

 

INTERF:

Defines how the printer is connected to the AS/400 system. Refer

 

to page 378 and 268 for further information on the interface

 

types.

 

MACROID:

An HP macro must be given an ID in the interval 0-32767. The

 

printer can store a number of different macros. If a macro is

 

down loaded with the same macro ID as one already resident in

 

the printer, the new macro definition will override the old one. If

 

you choose to work with several macros in the printer

 

simultaneously you should number the macros unambiguously.

AUTOMATIC:

This parameter defines if the macro should be executed on all

 

pages (*YES) or only when called from a macro definition

 

incorporated in the print data (*NO).

FLASHMEM:

This parameter indicates if the macro should be stored in e.g. the

 

optional Flash SIMM module on a printer. Valid values are:

 

*No

= Only downloaded to the memory of the printer.

 

*HP4

= Store in HP Flash SIMM.

OUTQ:

Here the output queue for the final printout is stated. The macro

 

will be transformed into a spool-entry with the filename

 

MACROnnnnn, where nnnnn is the macro ID. The description of

 

the spool entry will be the name of the overlay.

FORMTYPE:

This is the forms type you want the macro to have when placed

 

as a spool-entry on the output queue defined by OUTQ.

The output will be placed in the output queue with status HOLD(*YES) and SAVE(*YES).

User’s Manual for InterForm400® 417

Page 417
Image 417
Intermate i5, AS/400, iSeries Into the Hpmacro command, Defines the name of the file-set, in which you have defined, Types