F19: DSPPFM

This function works like F18, but prompts the commands DSPPFM for displaying the spool entry as a physical file. This is useful for revealing reprinted lines (bolding), which is not displayed with F18 DSPSPLF.

Remember to subtract the first 4 positions containing SKIP/SPACE information, when calculating coloumn positions in the DSPPFM view..

Considerations for Zebra overlays

G NOTE G

Creation of ZPL output in InterForm400 requires purchase of the ZPL module or the classic package.

For overlays intended to be used for label printers the Design Overlay screen will look like this:

Design ZEBRA overlay

 

ZEB300D

Overlay name

TEST

 

 

Overlay text

_______________________________________________

Label length

__.000

 

 

Label width

__.000

 

 

Temperature

_0_

-30 - 30

 

Print speed

2

2, 3, 4, 5, 6, 8

inches/second

Line spacing

040___

in 1/240 of an inch (*INPUT, 1-720)

Rotation

000___

(*INPUT, 0, 90, 180, 270)

Font

0012__

*INPUT, fontnumber

F4=List

Copy management

Y

(Y N)

 

F3=Exit

F4=Prompt

F11=Delete this overlay

F12=Cancel

F13=Set

print parameters

 

 

 

 

 

 

The especially Zebra related parameters are:

Label length/width:

The length and width of the labels to print on.

Temperature: The temperature to use for the printing head. This number is a relative value (-30 to 30) for the temperature to use for the print head of the Zebra printer. This value will be added to the Darkness value specified on the printers display. That is if Darkness is 10 and temperature is 5 the actual Darkness value for merges with this overlay will be 15. If the sum of temperature and Darkness is outside the range 0-30 the nearest value is used.

Print speed: Specify the printing speed in number of inches per second. Note, that the highest possible print speed varies from one model to another.

J TIP J

If you want to insert text, frames or images in reverse i.e. white on black background you can do it by first adding a frame with black filling (=pattern) and then place the text or

User’s Manual for InterForm400® 43

Page 43
Image 43