Additional parameters

Type additional info and press Enter. Press F12 to exit.

Job name AUTO_FORM job . . .

*OUTQ_____

*OUTQ, Name

Job description

*DEFAULT__

*DEFAULT, Name

Library

__________

 

Library list option . . . .

*JOBD_____

*CURRENT, *JOBD,

 

 

*SYSVAL, *NONE

Separator drawer

*NONE

*NONE, 1-9, 20-39

F12=Cancel

 

 

 

 

 

 

 

Output Queue:

Name of output queue, AFC should be monitoring for incoming

 

spool files (INPUT QUEUE). The output queue you intend to use

 

for AFC functions should not have a printer device attached.

 

The reason for this is that the AFC sub system only works on

 

spool entries that gets the status *RDY in the queue. If the queue

 

also had a printer device attached, you could risk that the jobs

 

would be printed before the AFC system managed to complete its

 

automatic functions. (See Getting Familiar with AFC, Example 2

 

for an alternative way of setting up AFC)

Library:

Insert library or leave blank to search library list.

Description:

For your own information.

Job name:

The contents of the field job name AUTO_FORM job is used as

 

name for the job in the subsystem, which performs the automatic

 

functions. It is recommended to use the same name as used for

 

the output queue.

Auto Start:

If Y is entered the AFC functions for this queue will be started

 

automatically after IPL or when the subsystem AUTO_FORM is

 

started.

 

If N is entered the subsystem job has to be started manually.

Code page:

This defines if a specific code page should be forced for the

 

spool entries processed by this AFC definition. *SYSVAL means

 

that the default code page specified for the system will be used,

 

unless a specific code page is defined as attribute for the spool

 

file.

Default Output Output Queue and Printer Type

Output Queue/

Library:A default output queue for the result of e.g. AFC merges can be entered here. This queue will be used for the AFC definition lines having *DEFAULT as keyword. For AFC definitions having a specific queue defined this default queue setting will be ignored.

If these fields are left blank, the keyword *DEFAULT will not be accessible in the AFC definition lines, i.e. a specific queue must be entered for each AFC definition line.

Printer Type/

Interface:Same functionality as above, but for Printer Type and Interface Type.

User’s Manual for InterForm400® 137

Page 137
Image 137
Intermate iSeries, i5, AS/400 manual Default Output Output Queue and Printer Type, Job name, Auto Start