Specify output queue for processed spooled files:

Specify output queue for processed spooled files

OSC300D

Output queue

:

OSC_OUTQ01

 

 

Library

:

APF3812

 

 

Type choices, press Enter.

 

 

 

Output queue

.

ARCHIVE

Output queue, *DELETE

 

Library

.

APF3812

 

 

All input spooled files will be moved to the specified output queue, or will be deleted if *DELETE is specified.

F3=Exit F12=Cancel

When the OSC jobs have been executed we can define what should happen with the original spool files, taken from the OSC output queue. As per above entry screen, we can define if we wish to delete the spool files or we could enter an output queue for archiving purposes.

Specify job priority:

Specify job priority

OSC300D

Output queue

:

OSC_OUTQ01

Library

:

APF3812

Type choices, press Enter.

 

Job priority (RUNPTY) . .

50 11-99

Form type

.

*OSC______

F3=Exit F12=Cancel

Above we enter the desired run priority of the OSC job, and the form type used for the merged spool files.

The OSC definition has now been completed and upon exit from the OSC definitions we will be asked to save the definition.

Now you only have to setup Auto Forms Control jobs to monitor the output queues AFC_INPUT1 and AFC_INPUT2.

User’s Manual for InterForm400® 257

Page 257
Image 257
Intermate iSeries, i5, AS/400 manual Specify output queue for processed spooled files, Specify job priority, Archive