Update AFC-functions attatched to output queues

AFC305D

Output queue . . . . . . :

AFC_INPUT1

 

 

 

Library

. . . . . . . :

APF3812

 

 

 

Seqnbr Funct

Form type

Save Jobname

Filename

Device file

Program

0001

1

DEMO

 

 

 

 

 

 

 

 

0002

6

Merge, Overlay: IF400DEMO Fileset: SAMPLE

 

Hold Spooled File

 

 

 

 

 

 

 

 

Seqnbr Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0,1

5

Move Spooled File

 

 

 

 

 

New output queue . . . .

. . . .

AFC_OUT1__

*DEFAULT, *USER

 

 

Library

. . . .

APF3812___

 

 

 

Hold output spooled file

. . . .

*NO_

*NO, *YES

 

 

Save output spooled file

 

*NO_

*NO, *YES

 

 

. . . .

 

 

 

 

 

F3=Exit

 

F13=Fold/Unfold

 

F12=Cancel

 

 

We want to send all spool entries with formtype *STD to the output queue AFC_OUT1 without adding any overlay. When we press Enter, we see the AFC function appear as the first line:

 

Update AFC-functions attatched to output queues

AFC305D

Output queue . . . . . . :

AFC_INPUT1

 

 

Library

. . . . . . . :

APF3812

 

 

Seqnbr Funct

Form type

Save Jobname

Filename Device file

Program

0001

5

*STD

 

 

 

 

 

Move spooled file, new outq: AFC_OUT1 library: APF3812

0002

1

DEMO

 

 

 

0003

6

Merge, Overlay: IF400DEMO Fileset: SAMPLE

 

Hold Spooled File

 

 

 

 

 

 

Seqnbr Function 0,1

F3=Exit

F5=Service

F13=Fold/Unfold

Step 5. Defining move of Print jobs with Formtype DEMO

Currently sequence line 3 defines that all files should be put on hold when they have been processed by line 1 and 2.

This means that currently the sample spool entry with form type DEMO is put on hold and stays in the queue. We now want to move this type of spool file to queue AFC_INPUT2, so it can be processed by the AFC definition for that queue.

We enter a sequence line between sequence line 2 and 3, meaning that we will move the demo spool entry, after it has been used to create a merged spool file on queue AFC_OUT1, but before it would get put on hold by sequence line 3:

We enter sequence line 2,1 and press Field Exit. We enter form type DEMO as the criteria for executing the move operation and we press Enter:

158User’s Manual for InterForm400®

Page 158
Image 158
Intermate iSeries, i5, AS/400 manual Defining move of Print jobs with Formtype Demo, Default, *User, APF3812