OUTDOOR UNIT INSTALLATION

Heat Controller, Inc.

INSTALLATION INSTRUCTIONS

SMA/SMH 18/24

OUTDOOR UNIT INSTALLATION

1. Outdoor Installation Precaution

Install the outdoor unit on a rigid base to prevent noise and vibration.

Locate the air outlet direction where the discharged air is not blocked. Ensure there are no obstacles blocking the unit’s air flow.

If the installation location is exposed to strong winds, place the unit length wise along a wall or use shield plates to protect against high winds.

If suspending the unit, the installation wall should be solid brick, concrete or of similar construction. If not, reinforce the supporting wall. The connections between the bracket and wall and the bracket and the air conditioner must be firm, stable and reliable. Consult all local and national building codes.

If suspending the unit, follow the instructions provided by the bracket manufacturer.

2. Drain Elbow Installation

89

Fit the seal into the drain elbow, then insert the drain elbow into the outdoor unit’s base pan hole, rotate 90° to securely assemble them. To discharge excessive condensate from the outdoor unit when in heating mode, connect the drain elbow to a drain hose (locally purchased).

8

Image 9
Contents INSTRUCTIONS INSTALLATIONSMA/SMH 18/24 Version C Single Zone Ductless Mini-SplitSystemPage INSTALLATION INSTRUCTIONS Installation PartsHeat Controller, Inc SMA/SMH 18/24INSTALLATION INSTRUCTIONS INDOOR UNIT INSTALLATION1. Attach the installation plate SMA/SMH 18/24INSTALLATION INSTRUCTIONS 2. Line Set and Condensate Drain LineHeat Controller, Inc SMA/SMH 18/24Page 5.Connecting Cables INSTALLATION INSTRUCTIONS 6. Piping and WrappingSMA/SMH 18/24 Heat Controller, Inc1. Outdoor Installation Precaution OUTDOOR UNIT INSTALLATION2. Drain Elbow Installation INSTALLATION INSTRUCTIONSINSTALLATION INSTRUCTIONS 3. Refrigerant Piping Connection2. Tightening Connection SMA/SMH 18/24INSTALLATION INSTRUCTIONS 4. Wiring ConnectionHeat Controller, Inc SMA/SMH 18/241. Air Purge AIR PURGE AND TEST OPERATION3. Test Operation 2. Gas Leak Check