INSTALLATION
Passive crossovers are directly dependent upon the speaker's impedance and component value for accuracy. When passive crossover components are used in multiple speaker systems, the crossover's effect on the overall impedance should be taken into consideration along with the speaker's impedance when determining amplifier loads.
! | CAUTION: These amplifiers are not recommended for impedance loads below 2Ω |
stereo and 4Ω bridged (mono). |
L
6dB/Octave Low-Pass
C
6dB/Octave High-Pass
L =
C = High-Pass (Capacitor)
For more information, see your
Authorized Rockford Fosgate Dealer.
Freq.
Hertz
80
100
130
200
260
400
600
800
1000
1200
1800
4000
6000
9000
12000
Speaker Impedance
2 OHMS | 4 OHMS | 8 OHMS |
L C | L C | L C |
4.1mH | 1000µF | 8.2mH | 500µF | 16mH | 250µF |
3.1mH | 800µF | 6.2mH | 400µF | 12mH | 200µF |
2.4mH | 600µF | 4.7mH | 300µF | 10mH | 150µF |
1.6mH | 400µF | 3.3mH | 200µF | 6.8mH | 100µF |
1.2mH | 300µF | 2.4mH | 150µF | 4.7mH | 75µF |
.8mH | 200µF | 1.6mH | 100µF | 3.3mH | 50µF |
.5mH | 136µF | 1.0mH | 68µF | 2.0mH | 33µF |
.41mH | 100µF | .82mH | 50µF | 1.6mH | 26µF |
.31mH | 78µF | .62mH | 39µF | 1.2mH | 20µF |
.25mH | 66µF | .51mH | 33µF | 1.0mH | 16µF |
.16mH | 44µF | .33mH | 22µF | .68mH | 10µF |
.08mH | 20µF | .16mH | 10µF | .33mH | 5µF |
51mH | 14µF | .10mH | 6.8µF | .20mH | 3.3µF |
34mH | 9.5µF | 68mH | 4.7µF | .15mH | 2.2µF |
25mH | 6.6µF | 51mH | 3.3µF | 100mH | 1.6µF |
REMOTE PUNCH BASS
Mounting and installation
1.Find a location, either under the dash or near the center console, that gives easy access to the remote.
2.Using the screws supplied, install the mounting clip with the tabs towards the back.
3.Route the cable for the remote and connect to both the remote and amplifier.
4.Slip the remote onto the mounting clip until it snaps into place.
5.Place the decal onto the remote and use the nut to hold the decal in place. Do not over tighten nut.
6.Install the knob onto the remote.
Mounting
Clip
Decal
Knob
Nut
9