Upgrading the Docking Station Firmware

Upgrading the Docking Station Firmware

The following accessory devices are firmware upgradeable:

MVP-TDS Table Top Docking Station (FG5965-10)

MVP-WDS Wall/Flush Mount Docking Station - Black (FG5965-11)

MVP-WDS Wall/Flush Mount Docking Station - Silver (FG5965-21)

This device is not given a unique device number which would ordinarily appear within the Online Tree tab of NetLinx Studio. It appears as a battery base below the target panel which it is a part of as seen below in FIG. 1.

Target Panel Device #

TDS/WDS

(station version)

NetLinx Studio Online Tree tab

Accessory’s corresponding firmware page

FIG. 1 Location of Firmware version information within NetLinx Studio

The only way to upgrade the firmware of these accessory items is to send the accessory’s firmware through a target panel. Its this panel’s device number which is entered within the Send to NetLinx Device transfer dialog in Studio.

Step 1: Prepare the Docking Station for firmware transfer via USB

Before beginning with this section:

Verify the MVP is securely attached to the docking station and communicating properly.

Verify that the panel is communicating from the mini-USB port to the Virtual NetLinx Master (VNM).

1.Configure the NetLinx Master for IP communication. Refer to the MVP-7500/8400 Operation/ Reference Guide (available online at www.amx.com) for information.

2.After the panel powers-up, press and hold the two lower buttons on both sides of the display for 3 seconds to continue with the setup process and proceed to the Setup page.

3.Press the Batteries button to open the Batteries page (FIG. 2).

MVP-TDS Table Docking Station for MVP Panels

9

 

 

Image 15
Contents MVP-TDS AMX Limited Warranty and Disclaimer FCC Information Page Table of Contents Page Overview SpecificationsFront Panel Components MVP-TDS docking station connectorsInterface Connector Pins and Functions InstallationConnecting a Power Supply MVP-TDS LED IndicatorsAfter the panel splash-screen disappears Connecting a USB Keyboard and Mouse to the MVP-TDSSystem message panel is properly docked Securing an MVP Panel to an MVP-TDSSecured MVP removal from an MVP-TDS Installing and Charging Batteries in the Docking StationsRemoving an MVP Panel from an MVP-TDS Unsecured MVP removal from an MVP-TDSInstalling an MVP-BP Battery into an MVP-TDS Page Prepare the Docking Station for firmware transfer via USB Upgrading the Docking Station FirmwareBatteries Upgrade the Docking Station firmware via USBDevice and System values Upgrading the Docking Station Firmware Page It’s Your World Take Control