Haier AB422ACERA, AB142ACEAA Error display For ERA series, Outdoor ambient temp. sensor failure

Page 18

16

 

For remote Failure description

Reason

Remarks

 

type, flash

 

 

 

 

times

 

 

 

1

Indoor ambient temp. sensor failure

Sensor broken down or short circuit for more than 2m continuously

 

2

Indoor coil temp. sensor failure

Sensor broken down or short circuit for more than 2m continuously

 

3

Outdoor ambient temp. sensor failure

Sensor broken down or short circuit for more than 2m continuously

 

4

Outdoor coil temp. sensor failure (compressor

Sensor broken down or short circuit for more than 2m continuously

 

 

 

discharging temp. sensor)

 

 

 

 

 

 

 

5

Over-current protection

CT check abnormal 3 times in 30m

 

6

High pressure abnormal

High pressure switch acts 3 times in 30m

 

7

Power supply abnormal

Fault phase, short of phase, out of balance greatly

 

 

 

Communication between wired

 

 

8

controller and indoor abnormal

Communication abnormal for more than 4m continuously

 

9

Communication between indoor and outdoor abnormal

Communication abnormal for more than 4m continuously

 

10

Drainage system abnormal

Float switch broken down for more than 25m continuously

 

11

Outside alarm signal input

Outside signal broken down for more than 10s

 

12

Gas pipe temp. sensor abnormal

Sensor broken down or short circuit for more than 2m continuously

 

13

Temperature protection malfunction

Solenoid valve act incorrectly 3 times continuously

 

14

Discharging temp. sensor abnormal

Sensor broken down or short circuit for more than 2m continuously

 

15

EEPROM abnormal

EEPROM data missing

 

16

Pressure abnormal(low pressure)

Low pressure switch acts in normal running

 

 

 

 

 

Resumable if

17

Compressor overheat

The discharging temperature is higher than 120degree

lower than 100

degree

18

Abnormal mode

Indoor operation mode is different with the running indoor unit.

 

19Outdoor coil B(suction temp sensor-for MRV II) Sensor broken down or short circuit for more than 2m continuously

20Outdoor discharging B(oil temp sensor-for MRV II) Sensor broken down or short circuit for more than 2m continuously

21

SPDU module temperature protection

Spdu module temperature is too high

shows resumable fault, * shows it is not resumable fault.

Error display ( For ERA series )

When Trouble Happens

Image 18
Contents Operation & Installation Manual No.0010577963Contents Disposal of the old air conditioner Machine is adaptive in following situation Applicable ambient temperature range For EAA seriesRefrigerating circuit is leak-proof For ERA seriesSafety cautions Dont dismantle the outlet of the outdoor unit Wiring LocationOperating noise Suction grill Introduction to Spare PartsFor series 142 Drain Hose Swing fenderClean the air filter MaintenanceClean the unit Clean indoor outdoor unitFor series 242 Install air filterClean Open inlet grillInstall swing plate Take off air-filter Take of inlet grill CleanInstall inlet grill Close inlet grillClean the air filter For series 362, 422, 482Instruction Seasonal Reserve Post-season Care Pre-season CareTrouble Shooting Followings are not malfuncitionOFF Insufficient cooling or heating When Trouble HappensCooled air blown out when heating Insufficient coolingError display For ERA series Outdoor ambient temp. sensor failureError display For EAA series Using Directions Customer Need-to-knowCustomer Need-to-know Installation Procedure Meanings of Warning and CautionsBefore Installation Selection of Installation PlaceDont discard any accessories until comp Preparation for the Installation Installation exampleCase of new ceiling Installation of Indoor UnitAfter installation on the ceiling Case of ceiling already existsInstallation of Water Drainage Pipe Pipe Tighten Amm Flare shape Size TorqueLimits of panel board installation After wiring When wiring is not completeWiring Wiring ExampleInstallation of Ornament Panel Mounting on high ceiling Installation of inlet grill and cover plate Haier Group