Haier AB142ACEAA, AB422ACERA, AB142ACERA operation manual Location, Wiring, Operating noise

Page 7

Cautions

Installation

Please ask the dealer or specialist to install, never try by the users themselves. After the installation please

be sure of the following conditions.

WARNING !

Please call dealer to install the air-conditioner.

Incorrect installation may cause water leaking, shock and fire hazard.

CAUTION !

Air-conditioner can't be installed in the envi- ronment with inflammable gases because the inflammable gases near to air-conditioner may cause fire hazard.

Installed electrical-leaking circuit breaker. It easily cause electrical shock without circuit breaker.

Connect earthing wire.

 

Earthing wire should not be con-

 

nected to the gas pipe, water pipe,

 

lightning rod or phone line, in-

 

correct earthing may cause shock.

Earthing

Use discharge pipe correctly to ensure efficient discharge.

Incorrect pipe use may cause water leaking.

[Location]

Air-conditioner should be located in well-vented and easily-accessible place.

Air-conditioner should not be located in the following places:

(a)Places with machine oils or other oil vapours.

(b)Seaside with high salt content in the air.

(c)Near to hot spring with high content of sulfide gases.

(d)Area with frequent fluctuation of voltage e.g. factory, etc.

(e)In vehicles or ships.

(f)Kitchen with heavy oil vapour or humidity.

(g)Near to the machine emitting electric-magnetic waves.

(h)Places with acid, alkali vapuor.

TV, radio, acoustic appliances etc are at least 1 m far away to the indoor unit, outdoor unit, power supply wire, connecting wire, pipes, otherwise images may be disturbed or noises be created.

As required, take measures against heavy snow.

[Wiring]

Air-conditioner should be equipped with special power supply wire.

[Operating noise]

Chose the following locations:

(a)Capable of supporting air-conditioner weight, don't increase operating noise and vibration.

(b)Hot vapour from outdoor unit outlet and ope- rating noise don't disturb neighbour.

No obstacles around the outdoor unit outlet.

5

Image 7
Contents No.0010577963 Operation & Installation ManualContents Disposal of the old air conditioner For ERA series Applicable ambient temperature range For EAA seriesRefrigerating circuit is leak-proof Machine is adaptive in following situationSafety cautions Dont dismantle the outlet of the outdoor unit Location WiringOperating noise Drain Hose Swing fender Introduction to Spare PartsFor series 142 Suction grillClean indoor outdoor unit MaintenanceClean the unit Clean the air filterOpen inlet grill Install air filterClean For series 242Close inlet grill Take off air-filter Take of inlet grill CleanInstall inlet grill Install swing plateFor series 362, 422, 482 Clean the air filterInstruction Pre-season Care Seasonal Reserve Post-season CareFollowings are not malfuncition Trouble ShootingOFF Insufficient cooling When Trouble HappensCooled air blown out when heating Insufficient cooling or heatingOutdoor ambient temp. sensor failure Error display For ERA seriesError display For EAA series Customer Need-to-know Using DirectionsCustomer Need-to-know Meanings of Warning and Cautions Installation ProcedureSelection of Installation Place Before InstallationDont discard any accessories until comp Installation example Preparation for the InstallationCase of ceiling already exists Installation of Indoor UnitAfter installation on the ceiling Case of new ceilingPipe Tighten Amm Flare shape Size Torque Installation of Water Drainage PipeLimits of panel board installation When wiring is not complete After wiringWiring Example WiringInstallation of Ornament Panel Mounting on high ceiling Installation of inlet grill and cover plate Haier Group