Outdoor unit

1.Installation of Outdoor Unit

Install according to Drawing for the installation of indoor and outdoor units

2.Connection of pipes

To bend a pipe, give the roundness as large as possible not to crush the pipe ,and the bending radius

should be 30 to 40 mm or longer.

Connecting the pipe of gas side first makes working easier. The connection pipe is specialized for R410A.

Half union

Flare nut

Torque wrench

Spanner

Forced fastening without careful centering may damage the threads and cause a leakage of gas.

Pipe Diameter

Fastening torque

Liquid side 6.35mm(1/4")

18N.m

Gas side 9.52mm(3/8")

42N.m

Be careful that matters, such as wastes of sands, etc. shall not enter the pipe.

The standard pipe length is 5m. If it is over 5m, the function of the unit will be affected. If the pipe has to be lengthened, the refrigerant should be charged, according to 20 g/m. But the charge of refrigerant must be conducted by professional air conditioner engineer. Before adding additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump,then charge additional refrigerant.

B

Outdoor unit

Outdoor unit

Indoor unit

A

A

 

Outdoor unit

 

B

B

Oil trap

 

Indoor unit

A

Indoor unit

 

 

CAUTION

In case A is more than 5m

Max.Elevation: Amax=10m

Max. Length: Bmax=15m

In case the elevation A is more than 5m,

In case the pipe length B is more than 10m,

oil trap shoud be installed every 5~7m

the refrigerant should be charged, according to 20 g/m.

3.Connection

Use the same method on indoor unit. Loosen the screws on terminal block and insert the plugs fully into terminal block, then tighten the screws.

Insert the cable according to terminal number in the same manner as the indoor unit.

If wiring is not correct, proper operation can not be carried out and controller may be damaged.

Fix the cable with a clamp.

4.Attaching Drain-Elbow

If the drain-elbow is used, please attach it as figure. (Note: Only for heat pump unit.)

6

Image 8
Contents Installation Manual Page Necessary Tools for Installation 3RZHU6RXUFH When the mounting plate is fixed side bar and lintel Indoor unitFixing the indoor unit body QGRRUXQLW Outdoor unit Connection of pipesPurging MethodTo use vacuum pump Power Source Installation Accesorio AccesorioComponentes opcionales para la instalación de los tubos EntubaciónUnidad interior  Fijación de la unidad exteriorUnidad exterior Tubo de líquido Ø 35 mm 1/4 Tubo de gas Ø 52 mm 3/8Cara exterior Unidad interiorInstalación de la unidad interior Unidad interior  Fijación de la unidad interiorDescarga de la unidad interior Entubación en otra direcciónCable de alimentación 3G1.5mm2 Unidad interiorUnidad exterior Instalación de la unidad exteriorConexión de los tubos ConexiónUnidad exterior Método de purga para utilizar unaAbrir Válvula de 2 vías L y las 3 vías G, y conecte el,QVWDODFLyQGHODIXHQWHGHDOLPHQWDFLyQ 3UXHEDGHLQVWDODFLyQ\HMHFXFLyQGHODSUXHED1RUHDOLFHHOGUHQDMHFRPRVHPXHVWUDDFRQWLQXDFLyQ ,QVHUWDUODWXHUFDFyQLFDAccessori AccessoriI modelli adottano il refrigerante R410A privo di HFC PiùAlimentazione Quando si fissa prima la piastra di montaggio Installazione dellelemento internoComponente interno Fissaggio del corpo dellelemento interno Smontaggio dellunità esternaCavo di alimentazione 3G1.5mm2 Installazione del componente esterno Componente esternoCollegamento dei tubi ConnessioneApre Chiude Valvola a 2 vie,QVWDOODLRQHGHOODVRUJHQWHGLDOLPHQWDLRQH Les modèles adoptent le réfrigérant R410A sans HFC Pièces accessoiresRepère Dimensions de fixation au sol de lunité extérieure Unité mm Unité intérieureUnité extérieure Tuyau à liquide Ø 35mm 1/4 Tuyau à gaz Ø 52mm 3/8Installation de lunité intérieure Unité intérieureCôté intérieur Trou mural Côté extérieur Épaisseur du murEnlever le cache du câblage Connecter le câble électrique intérieur/extérieurFixer le corps de lunité intérieure Unité intérieure Unité extérieure Installation de lunité extérieure Unité extérieureBranchement des tubes BranchementMéthode de purge Pour utiliser une Pompe à videOuvrir FermerSRXU5$ &RXSHUHWpYDVHUODWX\DXWHULHPYDVHPHQW IT Conformità Alle Direttive Europee PER I Modelli ES Conformidad Europea DE LAS Regulaciones Para LOS Modelos R410A GWP = Potencial de calentamiento global

HSU-09RD03/R2(SDB), HSU-12RD03/R2(SDB) specifications

Hitachi, a leading player in the technology and electronics sector, has made considerable advancements in the field of cooling and air conditioning systems with its HSU-12RD03/R2(SDB) and HSU-09RD03/R2(SDB) models. Designed to meet the needs of modern households, these air conditioning units combine efficiency, performance, and innovative technology.

The HSU-12RD03/R2(SDB) is a powerful model capable of delivering effective cooling or heating for larger living spaces, while the HSU-09RD03/R2(SDB) offers a more compact solution for smaller rooms. Both models utilize advanced inverter technology, which not only ensures faster cooling and heating but also provides energy savings. The inverter technology allows the units to adjust their compressor speed based on the indoor temperature, resulting in reduced energy consumption and stable comfort levels.

Another marquee feature of these models is their high Seasonal Energy Efficiency Ratio (SEER), which signifies their superior energy efficiency compared to standard air conditioning units. This makes them an ideal choice for environmentally conscious consumers looking to reduce their carbon footprint and lower energy bills.

Both HSU-12RD03/R2(SDB) and HSU-09RD03/R2(SDB) are equipped with innovative filtration systems that enhance indoor air quality. These filters capture dust, allergens, and other particulate matter, providing a cleaner and healthier living environment. The self-cleaning feature is another standout characteristic, as it helps to maintain the unit's performance over time by preventing the buildup of mold and bacteria.

Furthermore, the quiet operation of these air conditioning units is worth noting. With noise levels kept to a minimum, they ensure that comfort is maintained without disturbing daily activities or sleep.

In terms of control, Hitachi has incorporated smart technology in these models, allowing users to regulate temperatures via remote control or mobile applications. This user-friendly approach enhances convenience and allows for tailored climate control.

Overall, the Hitachi HSU-12RD03/R2(SDB) and HSU-09RD03/R2(SDB) air conditioning units represent a harmonious blend of technology, efficiency, and user-oriented features, making them ideal solutions for both residential and light commercial applications. With their robust performance, energy-saving capabilities, and smart functionalities, these units are set to redefine comfort in climate control.