Ericsson LBI-38732E manual Scanned Group Calls

Page 59

If the radio is programmed for forced private transmit operation, "FRCD PVT" will be displayed if an at- tempt is made to disable private transmit mode. It is not possible to transmit on this group/channel in clear mode.

If the radio does not have the correct encryption key loaded, "NO KEY #" will be displayed and the call will not be transmitted.

3.Continue with standard transmission procedures. A private mode access tone will be heard when the PTT button is pressed.

Scanned Group Calls

Receiving a scanned group call is the same as receiv- ing a selected group call. During the scan hang time, if the radio was programmed for autoselect, it will transmit back in the same mode it received the call. For example, if a clear group is entered in the scan list, it will only receive clear calls. If the same group was available in private and entered in the scan list, it can receive clear and private calls, provided autoselect was programmed in the radio. The user can select transmitting on the scanned or selected group. If a group is entered in the scan list more than once and in different modes (clear, digital, private), only the first occurrence of the group will be used.

59

Image 59
Contents LBI-38732E Operator’s Manual Page Table of Contents Edacs Trunked Mode Operation Scanning Conventional Channels Operating Rules and Regulations Safety Information Battery Charging and Care Page For Best Performance Extended Operations FCC Licensing Transceiver ServiceIntroduction User Interface RK II Portable Radio Top And Partial Left Panel Views Buttons and Knobs Page Keypad PUSH-TOTalk but TON PTTGROUP/CHANNEL Selection Page Display SYS Busy MessagesCC Scan Txemer TX Data Sysc on Frcd PVT Status IndicatorsPage Page Universal Device Connector UDC Call Originate Autokey Trunked Mode OnlyCall Queued Trunked Mode Only Alert TonesLow Battery Warning System Busy Trunked Mode OnlyCall Denied Trunked Mode Only Carrier Control TimerOperation Keypad LOCK/UNLOCK Low Battery Alert Transmit LockoutKey Press Alert Turning on the Radio S = X X X X XY = Z Z Z U T HL S Y S Menu K L = X X N U Y Y Y Y Y YN U K L G H T Page Feature Display Feature Encryption Display Serial Number ROM 12 Hex Digits Number Fields Feature Encryption Data StreamProsound Features EnabledSYSTEM/GROUP/CHANNEL Selection System Selection Primary function for these controlsDisplay registers the new system name on line one Group And Channel Selection Home EMERGENCY/HOME Button DefinitionVoice Modes Aegis and Voice Guard OperationClear Modes Aegis Digital ModeDtmf Aegis Private and Voice Guard Private Modes DSP ERRHardware Transferring Keys Into The Radio Displaying The Currently Used Cryptographic Key Number Key Zero Transmitting An Encrypted Call Private OperationReceiving An Encrypted Call Scanned Group Calls Page Receiving a Call Edacs Trunked Mode OperationSending a Call Conventional Failsoft Emergency Operation Scat OperationDeclaring An Emergency Call Receiving An Emergency CallWide Area System Scan Scanning Trunked SystemsMenu Selection ProSoundPriority System Scan Deleting Groups From a Scan List Pre-Programmed Keypad KeyScanning Trunked Groups Adding Groups To a Scan ListTurning Scan On Nuisance DeleteTurning Scan Off Programmable Entries Is pressed Individual CallsPage Call Storage Lists Sending An Individual Call Trunked Mode Only Telephone Interconnect Calls Receiving a Telephone Interconnect Call Trunked Mode OnlySending a Telephone Interconnect Call Trunked Mode Only Dtmf Overdial/Conventional Mode Telephone Interconnect Page Portable Data Data Displays Data On Operation Data Off OperationExiting Data Calls Scan Lockout ModeMenu Option Data Lockout ModeProFile Select Option Option Availability Status Operation STATUS/MESSAGE OperationMessage Operation Dynamic Regroup Operation Edacs Conventional P1 ScanMacro KEY Operation Emergency OperationSquelch Adjust 256K & UP Version Radios only Conventional Mode OperationMenu Selection Receiving a Call Sending a Call Page Tone Encode Transmission Using 5-Tone Signalling For Emergency DeclarationScanning Conventional Channels Adding Channels to a Scan List Nuisance Delete Deleting Channels from a Scan ListTurning Scan OFF Turning Scan onType 99 Decode Conventional only 100 101 Operating Rules and Regulations102 Operating Tips103 Battery PacksIntrinsically Safe Usage 104 Accessories105 GlossaryMonitor and receive calls from these groups 106Interconnect 107Page 109 110 Warranty111 NICKEL-CADMIUM Battery WarrantyEmergency Numbers

LBI-38732E specifications

The Ericsson LBI-38732E is a prominent piece of communication equipment that showcases advanced features and cutting-edge technologies intended for enhancing network performance and reliability. This model is part of Ericsson's extensive portfolio designed for telecommunications service providers and enterprises looking for robust and scalable solutions.

One of the main features of the LBI-38732E is its high-capacity processing capabilities. It is engineered to handle large volumes of data traffic, ensuring seamless connectivity even during peak usage times. The processing architecture is optimized for low latency, which is critical for applications requiring real-time responsiveness, such as voice over IP and video conferencing.

The LBI-38732E leverages multiple advanced technologies including Software-Defined Networking (SDN) and Network Functions Virtualization (NFV). These technologies allow operators to enhance their network flexibility and agility, facilitating easier management and deployment of new services. By using SDN, the LBI-38732E enables dynamic resource allocation, which can significantly improve operational efficiency.

In addition, the device supports multi-access edge computing (MEC), bringing processing capabilities closer to the end-user. This functionality reduces latency and enhances user experiences, particularly for applications such as augmented reality, IoT, and real-time analytics.

Another key characteristic of the LBI-38732E is its integration with Ericsson's broader ecosystem of network management tools. This integration ensures operators have access to advanced analytics and monitoring capabilities, enabling proactive maintenance and swift issue resolution. The platform also allows for seamless updates and upgrades, ensuring that the technology stays current with evolving market demands.

Furthermore, the LBI-38732E is designed with security as a fundamental aspect. It includes advanced encryption and authentication features to protect sensitive data and ensure the integrity of communications. These security measures are crucial, especially in an era where cyber threats are increasingly sophisticated.

Overall, the Ericsson LBI-38732E stands out as a versatile and powerful solution for modern telecommunications networks. Its innovative features, combined with robust security and management capabilities, make it a valuable asset for operators aiming to deliver high-quality services while adapting to the rapidly changing technological landscape.