Uniden UH015sx manual Default Settings, Selcall Tone Frequency List

Page 36

UNIDEN Model uh015sx UHF CB Radio

Group Call Mode

4.When finished, press MENU /ENTER to store. Three successive beeps are heard.

5.Press MENU /ENTER for 2 seconds to exit. The radio returns to normal operation.

-or-

Turn the Channel Selector to go to the next programmable parameter.

Default Settings

A.

RX Selcall ID :

00000

B.

TX Selcall ID :

00000

C.

Tone Period :

40mSec

D.

Lead-in Delay :

500mSec

E.

Lead-in Tone :

Tone ‘1’

F.

Alarm Mode :

Auto

G.

Group Call Mode :

01

Be sure that the Tone Format (5 Tone or 6 Tone), Tone Period Setting and the Lead-in Tone for all radios in your group are the same. Otherwise you will not be able to effectively call one another.

Selcall Tone Frequency List

TONE No.

TONE

TONE No.

TONE

 

FREQUENCY (Hz)

 

FREQUENCY (Hz)

0

1981

8

1747

1

1124

9

1860

2

1197

A (Group)

2400

3

1275

B

930

4

1358

C

2247

5

1446

D

991

6

1540

E (Repeat)

2110

7

1640

F

1055

 

 

 

 

35

Image 36
Contents Uniden Model uh015sx UHF CB Radio Contents Contents Features Preventative MaintenanceTroubleshooting Controls/Connectors Controls and ConnectorsIndicators IndicatorsPackage Contents Mounting Options Mounting the complete radio Transceiver with Display UnitRemote mounting of the Display Unit Fixing the Display Rear BracketSetting the Squelch OperationSelecting a Channel/POLICE and CB Channel Groups MonitorUsing Repeater Channels Duplex Mode TransmittingOpen Scan OS Mode Operating the uh015sx in Duplex ModeScanning Group Scan GS Mode Wide Band Searching Press and holdRX Channels Manual ProgrammingCopying a Police frequency to a RX Channel Copying a frequency found using Search to a RX Channel Menu /ENTERVOX Operation optional VOX headset required Programming the Instant Priority ChannelRecalling the Instant Channel Ctcss Continuous Tone Coded Squelch System DCS Digitally Coded SquelchSelective Calling OutlineReceiver Quieting Call Receiving To ActivateTone Squelch Scanning Tone CallingTX Tone Selcall Programming Group Calling TX Selcall ID FormatTone Selcall Programming Reciever Selcall ID Programming Your Selcall IDFrom 6 to 5 Tone Format setting Selecting 5 or 6 Tone Format From 5 to 6 Tone FormatOther Selcall Parameters Selcall ID Tone PeriodLead-in Delay Lead-in Delay Programming Lead-in Tone If you want to remove the Lead-in Tone choose the space Bar Alarm Mode Alarm ModeCall Alarm Continue Mode Alarm Mode Group Call Mode Default Settings Selcall Tone Frequency ListUHF CB Channels & Frequencies Please follow these guidelines for channel use in AustraliaCtcss & DCS Code List Warranty Uniden Australia Pty Limited/Uniden New Zealand Limited