OPERATION
SPACING : x.xx mm
WELD.TIME : xxmin
Display of the step between each bead, (distance in mm, 1 mm equals to 0.04 inch) and estimate welding time in minutes.
SETTING SHAPE X ?
NO - VALID
SETTING SHAPE X ?
YES - VALID
Option to repeat the same shape or change the size and shape as previously indicated.
During welding:
RETURN TORCH TO
INITIAL POINT
Torch moves to starting point of the first bead.
WELDING CYCLE
BEAD xxx/yyy
Shows the bead’s number in welding, « xxx », and the to- tal number of beads of the whole resurfacing of the area, «yyy».
MOVE TORCH
Torch will moves to retracting point after bead.
VALID TO START
FOLLOWING BEAD
Press VALID key to start the next bead.
END LAYER N : 1
LAYER N : 2 - VAL
If VALID key is pressed, you will have to set anew welding area. (As previously seen).
If RESET key is pressed:
NEUTRAL POINT ?
TRANSPORT - VALID
Allow to place the torch in « Parking » position.
If VALID key is pressed, torch will move to « Parking » posi- tion.
If RESET key is pressed, back to message:
HELLO
STOP AND RESTART OF WELDING CYCLE
During the welding, in whatever mode you have selected, stopping the welding cycle is always possible:
Pressing the RESET key will stop the weld cycle.
STOP CYCLE
RESTART CYCLE ?
To restart the welding cycle, press VALID key.
According to what mode you are using, a correction of the exact positioning of the torch during the stopping can be done:
To stop the welding cycle, press the RESET key.
ERROR MESSAGES
During the setting of the points, some errors message can appear:
Set Position O2:
MIN LEN : 30mm !
LENGTH : xx mm
The distance between points Position O1 and Position O2 must be minimum or equal to 30mm on « X » axis. (This mes- sage will be displayed only if the distance between Position O1 and Position O2 < 30mm). Note : this distance (30mm equals to 1.18 inch) is set in the parameters menu.