TROUBLESHOOTING
| The « ON » TRANSLAMATIC‘s green light does not work | |
| PROBABLE CAUSE | CHECKS AND REMEDYS |
| « ON/OFF » switch | Check its good position and its good working |
|
| order |
| Alimentation’s cable cutted | Check the alimentation’s cable |
| Alimentation’s plug | Check the alimentation’s plug |
| Alimentation’s fuse or circuit breaker | Check the primary alimentation |
| The « ON » TRANSLAMATIC‘s green light works but the Charlie box does not work | |
| PROBABLE CAUSE | CHECKS AND REMEDYS |
| Link cable between the TRANSLAMATIC and | Check the connexions or/and change the cable |
| the Charlie box |
|
| Charlie box’s fuse | Check the fuse |
| Respect the « ON »process order | Put « ON » the Translamatic before putting the |
|
| Charlie box “ON”. |
| Charlie box | Try with another Charlie box |
| Interface card | Check if the interface card alimentation’s green |
|
| light is alight during the cycle. Call our After |
|
| Sales Dpt |
| Stabilized alimentation out of service | Check the alimentation’s tension, normally 27V in |
|
| CC. |
|
| Call our After Sales Dpt |
| The welding support head does | not move on one or several axis |
| PROBABLE CAUSE | CHECKS AND REMEDYS |
| Charlie box | Try with another Charlie box |
| Charlie box keyboard | Check the good working order of the keyboard’s |
|
| contacts. Check the good working order of the |
|
| keyboard using it in the test mode for example. |
|
| Call our After Sales Dpt |
| Interface card | Check the connexions |
|
| Check if the card’s lights are alight during a |
|
| moving command. Call our After Sales Dpt |
| Axis engine’s cards | Check if the card’s lights are alight during a |
|
| moving command. |
|
| Switch the connexions between the 2 engines and |
|
| the recheck the moving of the torch (the |
|
| movements are reversed) |
|
| Call our After Sales Dpt |
| Translation’s screw mechanically blocked | Check if the screw is not |
|
| bumpers or on the ball bearing or on the cardan. |
|
| Unscrew manually the screw if it is possible. |
|
| Call our After Sales Dpt |
| Uncontrolled speed of the torch and/or | no high speed and/or speed not as usual. |
| PROBABLE CAUSE | CHECKS AND REMEDYS |
| Charlie box | Try with another Charlie box |
|
| Change the Charlie box card |
22 - RW30 USER MANUAL |
|