Lincoln Electric SP-135T manual Welding Capability, Limitations, Controls and Settings

Page 15

B-2

OPERATION

B-2

 

 

 

No external shielding gas is required when used with Lincoln Innershield .035” (0.9 mm) NR®-211- MP electrode.

Accommodates both 4” (100 mm) diameter and 8” (200 mm) diameter spools of wire.

5.Gun Trigger - Activates welding output, wire feed, and gas solenoid operation. Releasing the trigger deactivates welding and simultaneously activates the “burnback” function so that the welding wire does not stick in the weld puddle.

WELDING CAPABILITY

The SP-135T is rated at 90 amps, 19 volts, at 20% duty cycle on a ten minute basis. It is capable of high-

er output currents at lower duty cycles.

1

 

LIMITATIONS

Arc Gouging cannot be performed with the SP-135T. The SP-135T is not recommended for pipe thawing or TIG welding.

CONTROLS AND SETTINGS

2

3

DO NOT SWITCH

WHEN WELDING

SP-135T

Refer to Figure B.1a.

1.Control Power ON/OFF Switch

— When the power is on the fan motor will run and air will be exhausted out the louvers in the front of the machine. The weld- ing output and wire feeder remain off until the gun trigger is pressed.

2.Wire Speed Control — Controls the wire feed speed from 50 – 300 in /min (1.3 – 7.6 m/min). The control can be preset on the dial to the setting specified on the SP- 135T Application Chart located on the inside of the wire feed section door.

3.Voltage Control — A 4-posi- tion tap selector switch gives full range adjustment of power source output voltage. Do not switch while welding.

OFF

ON

WIRE SPEED

ARC VOLTS

FIGURE B.1a

+

4

-

5

FIGURE B.1b

Refer to Figure B.1b.

4.Circuit Breaker – Protects machine from damage if maximum output is exceeded. Button will extend out when tripped (Manual reset).

SP-135T

Image 15 Contents
SP-135T California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyMaster Table of Contents for ALL Sections Technical Specifications SP-135T InstallationSafety Precautions Identify and Locate ComponentsElectric Shock can kill Stacking Work Clamp InstallationSelect Suitable Location Output ConnectionsGAS Connection GUN InstallationWork Cable Installation Connecting Gun Cable to the SP-135TFigure A.5 Input Connections Code Requirements for Input ConnectionsRequirements For Rated Output Recommended Processes Design FeaturesOperation General DescriptionControls and Settings Welding CapabilityLimitations Wire Loading Welding OperationsSequence of Operation Wire Threading Friction Brake AdjustmentCleaning Tip And Nozzle Process GuidelinesMaking a Weld Changing Machine Over to Feed Other Wire Sizes Welding with Gmaw MIGOverload Protection Application Chart Innershield Fcaw Conversion AccessoriesOptional Accessories K586-1 Deluxe Adjustable Gas RegulatorReplacement Parts 2ACCESSORIESC-2Maintenance Maintenance Safety PrecautionsRoutine Maintenance Contact Tip Cable Liner Drive Roll GUN and Cable MaintenanceConfiguration of Components in Wire Feeding System For Magnum 100L GUNComponent Replacement Procedures Changing the Contact TIPChanging Drive Roll Changing Liner GUN Handle PartsLiner trim length HOW to USE Troubleshooting Guide TroubleshootingRecommended Course of Action Problems Possible Areas Symptoms MisadjustmentsAuthorized Field Service Contact your local LincolnFacility Welding Problems Diagrams SP-135T SP-135T Precaucion Warnung