Lincoln Electric SP-135T manual Process Guidelines, Making a Weld, Cleaning Tip And Nozzle

Page 18

B-5

OPERATION

B-5

 

 

 

Contact Tip

Wire Electrode

3/8"– 1/2"(10-13mm) Contact Tip to Work Distance(CTWD)

FIGURE B.6

Making A Weld

1.See “Process Guidelines” in this section for selec- tion of welding wire and shielding gas and for range of metal thicknesses that can be welded.

2.See the Application chart on the inside of the wire feed compartment door for information on setting the SP-135T controls. Refer to Table B.1 for alu- minum and stainless wire.

3.Set the Voltage (“V”) and Wire Speed (“olo’”) con- trols to the settings suggested for the welding wire and base metal thickness being used, refer to Applications chart on the inside of the wire drive compartment door.

4.Check that the polarity is correct for the welding wire being used and that the gas supply, if required, is turned on.

5.When using Innershield electrode, remove the gas nozzle and install the gasless nozzle. This will improve visibility of the arc and protect the gas dif- fuser from weld spatter. Refer to the MAINTE- NANCE section for details on nozzle replacement.

GUN CABLE

WORKPIECE

ARC

WORK CLAMP

FIGURE B.7

6.Refer to Figure B.7. Connect work clamp to metal to be welded. Work clamp must make good elec- trical contact to the workpiece. The workpiece must also be grounded as stated in “Arc Welding Safety Precautions” in the beginning of this manu- al.

7.Position gun over joint. End of wire may be lightly touching the work.

8.Lower welding helmet, close gun trigger, and begin welding. Hold the gun so the contact tip to work distance is about 3/8 inch (10 mm).

9.To stop welding, release the gun trigger and then pull the gun away from the work after the arc goes out.

10.When no more welding is to be done, close valve on gas cylinder (if used), momentarily operate gun trigger to release gas pressure, and turn off the SP-135T.

Cleaning Tip And Nozzle

Clean the contact tip and nozzle to avoid arc bridging between the nozzle and contact tip which can result in a shorted nozzle, poor welds and an overheated gun. Hint: Anti-stick spray or gel, available from a welding supply distributor, may reduce buildup and aid in spat- ter removal.

PROCESS GUIDELINES

The SP-135T can be used for welding mild steel using the GMAW, single pass, process which requires a supply of shielding gas or it can be used for the self- shielded, Innershield® process (FCAW).

The recommended gases and electrodes for GMAW are welding grade CO2 gas or an argon-CO2blended gas (75 to 80% argon and 25 to 20% CO2) and .025" (0.6 mm) diameter Lincoln Super Arc L-56 mild-steel welding wire, supplied on 12-1/2 lb (5.7 kg) spools.

The recommended electrode for the self-shielded process is . 035” (0 . 9 mm) diameter Lincoln Innershield® NR-211-MP on 10 lb (4.5 kg) spools. This electrode can be used for all position welding of

20gauge (1.0 mm) through 5/16" (8 mm) steel. Thickness of 1/4" (6 mm) and 5/16" (8 mm) require multiple passes. This wire can also be used for the welding of galvanized coated sheet metal.

SP-135T

Image 18 Contents
SP-135T Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationMaster Table of Contents for ALL Sections Installation Technical Specifications SP-135TSafety Precautions Identify and Locate ComponentsElectric Shock can kill Output Connections Work Clamp InstallationSelect Suitable Location StackingConnecting Gun Cable to the SP-135T GUN InstallationWork Cable Installation GAS ConnectionFigure A.5 Input Connections Code Requirements for Input ConnectionsRequirements For Rated Output General Description Design FeaturesOperation Recommended ProcessesControls and Settings Welding CapabilityLimitations Wire Loading Welding OperationsSequence of Operation Friction Brake Adjustment Wire ThreadingCleaning Tip And Nozzle Process GuidelinesMaking a Weld Changing Machine Over to Feed Other Wire Sizes Welding with Gmaw MIGOverload Protection Application Chart K586-1 Deluxe Adjustable Gas Regulator AccessoriesOptional Accessories Innershield Fcaw Conversion2ACCESSORIESC-2 Replacement PartsMaintenance Maintenance Safety PrecautionsRoutine Maintenance For Magnum 100L GUN GUN and Cable MaintenanceConfiguration of Components in Wire Feeding System Contact Tip Cable Liner Drive RollComponent Replacement Procedures Changing the Contact TIPChanging Drive Roll Changing Liner GUN Handle PartsLiner trim length Troubleshooting HOW to USE Troubleshooting GuideProblems Possible Areas Symptoms Misadjustments Recommended Course of ActionAuthorized Field Service Contact your local LincolnFacility Welding Problems Diagrams SP-135T SP-135T Precaucion Warnung