Lincoln Electric SP-135T manual Component Replacement Procedures, Changing the Contact TIP

Page 25

D-3

MAINTENANCE

D-3

 

 

 

COMPONENT

REPLACEMENT

PROCEDURES

CHANGING THE CONTACT TIP

1.Refer to Figure D.2. Remove the gas nozzle from the gun by unscrewing counter-clockwise.

2.Remove the existing contact tip from the gun by unscrewing counter-clockwise.

3.Insert and hand tighten desired contact tip.

4.Replace gas nozzle.

CHANGING DRIVE ROLL

The drive roll has two grooves; one for .023" – .025" (0.6 mm) solid steel electrode and a larger knurled groove for .030" (0.8 mm) solid and .035" (0.9 mm) flux-cored steel electrode. As shipped, the drive roll is installed in the .030"/.035" (0.8/0.9 mm) position.

If .023" – .025" (0.6 mm) wire is to be used, the drive roll must be reversed as follows:

1.Connect the machine to its rated input power per instructions in Installation section.

2.Release the spring-loaded idle arm tensioner,Item 2, and lift the idle roll arm, Item 3, away from the drive roll, Item 1. (See Figure D.1)

3.Turn the power switch to ON (marked “I”).

4.Set the wire speed to minimum and jog the drive unit with the trigger switch until the drive roll set screw is facing up.

CAUTION

When inching the welding wire, the drive rolls, gun connector block, and gun contact tip are energized relative to work and ground and remain energized for several seconds after the gun trig- ger is released.

5.Turn the power switch to OFF (marked “O”).

6.Loosen the drive roll set screw with the 5/64" (2.0 mm) hex wrench supplied.

7.Remove the drive roll, flip over and reinstall with the

.023 – .025" (0.6 mm) groove (the smaller groove) closest to the gearbox.

8.Push a length of straightened welding wire through the wire feeder guide tubes and adjust the position of the drive roll so that the groove is centered on the wire. Make certain the set screw is located on the flat portion of the shaft and tighten.

FIGURE D.1

3

2

1

SP-135T

Image 25 Contents
SP-135T California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyMaster Table of Contents for ALL Sections Technical Specifications SP-135T InstallationIdentify and Locate Components Safety PrecautionsElectric Shock can kill Select Suitable Location Work Clamp InstallationOutput Connections StackingWork Cable Installation GUN InstallationConnecting Gun Cable to the SP-135T GAS ConnectionFigure A.5 Code Requirements for Input Connections Input ConnectionsRequirements For Rated Output Operation Design FeaturesGeneral Description Recommended ProcessesWelding Capability Controls and SettingsLimitations Welding Operations Wire LoadingSequence of Operation Wire Threading Friction Brake AdjustmentProcess Guidelines Cleaning Tip And NozzleMaking a Weld Welding with Gmaw MIG Changing Machine Over to Feed Other Wire SizesOverload Protection Application Chart Optional Accessories AccessoriesK586-1 Deluxe Adjustable Gas Regulator Innershield Fcaw ConversionReplacement Parts 2ACCESSORIESC-2Maintenance Safety Precautions MaintenanceRoutine Maintenance Configuration of Components in Wire Feeding System GUN and Cable MaintenanceFor Magnum 100L GUN Contact Tip Cable Liner Drive RollChanging the Contact TIP Component Replacement ProceduresChanging Drive Roll GUN Handle Parts Changing LinerLiner trim length HOW to USE Troubleshooting Guide TroubleshootingRecommended Course of Action Problems Possible Areas Symptoms MisadjustmentsContact your local Lincoln Authorized Field ServiceFacility Welding Problems Diagrams SP-135T SP-135T Precaucion Warnung