A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS – SP-135T

INPUT – SINGLE PHASE ONLY

Standard Voltage/Frequency

120V/60Hz

Input Current

20 Amps - Rated Output

Duty Cycle

20% Duty Cycle

Welding Current Range

25-135 Amps

RATED OUTPUT

Amps

90

OUTPUT

Maximum-Open Circuit Voltage

29V

Volts at Rated Amperes

19

Wire Speed Range

50 - 300 in/min

(1.3 - 7.6 m/min)

RECOMMENDED INPUT CABLE AND FUSE SIZES

 

 

 

 

 

 

 

 

Fuse or

 

 

 

Output Mode

Input Voltage

Breaker Size1

Input Amps

Power Cord

Extension Cord

 

 

 

 

 

 

 

 

 

 

 

Three Conductor

 

 

 

 

 

#14 AWG

 

 

 

 

 

(2.1 mm2) or Larger

RATED

120V/60Hz

20 Amp

20

15 Amp, 125V,

Up to 25 Ft. (7.6 mm)

 

 

 

 

Three Prong Plug

Three Conductor

 

 

 

 

(NEMA Type 5-15P)

#12 AWG

 

 

 

 

 

(3.3 mm2) or Larger

 

 

 

 

 

Up to 50 Ft. (15.2 mm)

 

 

 

 

 

 

PHYSICAL DIMENSIONS

Height

Width

Depth

Weight

12.0 in

9.75 in

16.5 in

48 Ibs

305 mm

248 mm

419 mm

21.8 kg

 

 

 

 

1If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.

SP-135T

Image 8 Contents
SP-135T Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationMaster Table of Contents for ALL Sections Installation Technical Specifications SP-135TElectric Shock can kill Safety PrecautionsIdentify and Locate Components Work Clamp Installation Select Suitable LocationOutput Connections StackingGUN Installation Work Cable InstallationConnecting Gun Cable to the SP-135T GAS ConnectionFigure A.5 Requirements For Rated Output Input ConnectionsCode Requirements for Input Connections Design Features OperationGeneral Description Recommended ProcessesLimitations Controls and SettingsWelding Capability Sequence of Operation Wire LoadingWelding Operations Friction Brake Adjustment Wire ThreadingMaking a Weld Cleaning Tip And NozzleProcess Guidelines Overload Protection Changing Machine Over to Feed Other Wire SizesWelding with Gmaw MIG Application Chart Accessories Optional AccessoriesK586-1 Deluxe Adjustable Gas Regulator Innershield Fcaw Conversion2ACCESSORIESC-2 Replacement PartsRoutine Maintenance MaintenanceMaintenance Safety Precautions GUN and Cable Maintenance Configuration of Components in Wire Feeding SystemFor Magnum 100L GUN Contact Tip Cable Liner Drive RollChanging Drive Roll Component Replacement ProceduresChanging the Contact TIP Liner trim length Changing LinerGUN Handle Parts Troubleshooting HOW to USE Troubleshooting GuideProblems Possible Areas Symptoms Misadjustments Recommended Course of ActionFacility Authorized Field ServiceContact your local Lincoln Welding Problems Diagrams SP-135T SP-135T Precaucion Warnung