Lincoln Electric S350 manual Basic Machine Problems

Page 34

E-5

TROUBLESHOOTING

E-5

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Basic Machine Problems

Input fuses keep blowing

1.

Improperly sized input fuses.

1.

Make sure fuses are properly

 

 

 

 

 

 

sized. See installation section of

 

 

 

 

 

 

this manual for recommended

 

 

 

 

 

 

sizes.

 

 

 

 

 

 

 

 

 

 

2.

Improper Weld Procedure requir-

2.

Reduce output current, duty

 

 

 

 

ing output levels in excess of

 

cycle, or both.

 

 

 

 

machine rating.

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Major physical or electrical dam-

3.

Contact your local authorized

 

 

 

 

age is evident when the covers

 

Lincoln Electric Field Service

 

 

 

 

are removed.

 

facility for technical assistance.

 

 

 

 

 

 

 

Machine will not power up (no lights)

1.

No Input Power

1.

Make sure input supply discon-

 

 

 

 

 

 

nect has been turned ON. Check

 

 

 

 

 

 

input fuses. Make certain that the

 

 

 

 

 

 

Power Switch (SW1) on the

 

 

 

 

 

 

power source is in the “ON” posi-

 

 

 

 

 

 

tion.

 

 

 

 

 

 

 

 

 

 

2.

Input voltage is too low or too

2.

Make certain that input voltage is

 

 

 

 

high.

 

correct, according to the Rating

 

 

 

 

 

 

Plate located on the rear of the

 

 

 

 

 

 

machine.

 

 

 

 

 

 

 

Machine wonʼt weld, canʼt get any

1.

Input voltage is too low or too high.

1.

Make certain that input voltage is

output.

 

 

 

 

correct, according to the Rating

 

 

 

 

 

 

Plate located on the rear of the

 

 

 

 

 

 

machine.

 

 

 

 

 

 

 

 

 

 

2.

Thermal Error.

2.

See “Thermal LED is ON” sec-

This problem will normally be

 

 

 

 

tion.

accompanied by an error code. See

 

 

 

 

 

 

3.

Secondary current limit has been

3.

Possible short in output circuit. If

“Status Light” section of this docu-

ment for additional information.

 

 

exceeded. (see error 54)

 

condition persists, contact an

 

 

 

3a. Input control board fault (see

 

authorized Lincoln Electric Field

 

 

 

 

input control board error status).

 

Service facility.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

POWER WAVE® S350

Image 34
Contents Power Wave S350 Safety Depends on YouSafety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents Installation Technical Specifications Power Wave S350Storage Temperature Range Model Height Width Depth WeightOperating Temperature Range Process Output Range AmperesFalling Equipment can Cause injuryInput Connection Input Fuse and Supply Wire ConsiderationsPower Cord Replacement Input Voltage SelectionSmaw Stick Welding Connection DiagramsGtaw TIG Welding Gmaw MIG WeldingMIG Process Recommended Work Cable Sizes for ARC Welding Output Cable Guidelines Table A.1Table A.2 Remote Sense Lead SpecificationsCable Inductance and ITS Effects on Welding WaveElectrode Voltage Sensing Work Voltage SensingIf Sense Leads are not Used Voltage Sensing Considerations for Multiple ARC SystemsIf Sense Leads are Used Figure A.8 Connection Between Power Source and Ethernet Networks Product specific Installation InstructionsControl Cable Connections Operation Safety PrecautionsElectric Shock can Kill Equipment Limitations Product DescriptionRecommended Processes and Equipment Product SummaryPIN Connector Optional Design FeaturesLoaded with Standard Features Case Front ControlsCase Back Controls See Figure B.2 for Code See Figure B.2a for CodeNON-SYNERGIC Welding Modes Common Welding ProceduresMaking a Weld Synergic Welding ModesNon Synergic CV Constant Voltage WeldingSynergic CV All CV ModesFigure B.4 KITS, Options and Accessories AccessoriesGeneral Options Order K875 Accessory KIT 400 AMP Order K704 Remote Output ControlPeriodic Maintenance MaintenanceRoutine Maintenance Calibration SpecificationTroubleshooting HOW to USE Troubleshooting Guide Using the Status LED to Troubleshoot System Problems Table E.1Error Code # Indication Main Control Board Status LightInput Control Board Basic Machine Problems Weld and Arc Quality Problems Troubleshooting Ethernet Diagrams NumberingcavityDimension Print 27.43 13.91 18.81 18.36Precaucion Warnung