INSTALLATION

A-2

 

 

 

INSTALLATION

WARNING

FALLING EQUIPMENT can cause injury.

• Do not lift this machine using lift bail if it is equipped with a heavy

accessory such as trailer or gas cylinder.

Lift only with equipment of adequate lifting capacity.

Be sure machine is stable when lifting.

The machine should be located in a clean, dry place where there is free circulation of clean air, such that air movement entering the front and exiting the back will not be restricted. Dirt and dust that can be drawn into the machine should be kept to a minimum. Failure to observe these precautions can result in excessive operating temperatures and nuisance shutdown of the machine.

The Idealarc R3R welders can be stacked three high when the following precautions are observed:

1.Be sure the bottom machine is on a firm, level sur- face suitable for the total weight [up to 1340 pounds (608 kg)] of the stacked machines.

2.Stack the machines with the fronts flush. Be certain the pins on the top front corners of the lower machines fit through the holes in the base rails of the upper machines.

3.No unit heavier than the bottom unit should be stacked on top of it. For example, an R3R 500-I shall not be slacked on top of an R3R 400-I, but an R3R 400-I may be stacked on top of an R3R 500-I.

INPUT POWER CONNECTION WARNING

ELECTRIC SHOCK can kill.

Have an electrician install and ser- vice this equipment.

Turn the input power off at the fuse box before working on equipment.

Do not touch electrically hot parts.

Remove the rear access panel. Connect the three phase input power to the three line terminals on the input contactor, and the earth ground lead to the

ground stud marked with the symbol. Install the reconnect panel for the proper input voltage per the diagram pasted inside the access panel cover.

 

 

 

Copper Wire Size

 

 

Input

 

Type 75°C in Conduit

Super Lag

 

 

 

 

R3R

Volts

Amps

3 Input

1 Ground

Fuse Size

Welder

50/60 Hz

Input

Wires

Wire

in Amps

 

 

 

 

 

 

 

220 - 230

103

4

6

150

600-I

380 - 400

60

8

8

90

 

440 - 460

52

8

8

70

 

 

 

 

 

 

DUTY CYCLE

The maximum output rating of this welder is at a 35% duty cycle. Duty cycle is based on a ten minute period. Therefore, the welder can be operated at the maximum rated output for 3.5 minutes out of every 10 minute period without overheating.

Failure to follow these instructions can cause immedi- ate failure of components within the machine.

CAUTION

When powering welder from a generator be sure to turn off welder first, before generator is shut down, in order to prevent damage to welder!

------------------------------------------------------------------------

OUTPUT CONNECTIONS

With the machine power switch off, the output leads are connected to the Magnum™ Twist-Mate™ output terminals marked “–” and “+”. They are located at the lower right and lower left corners of the front panel. Strain relief for the electrode and work cables is pro- vided by routing the leads through the rectangular holes in the base before the connections to the output terminals are made. Twist-Mate Lead plugs must be installed to the output cables before connections can be made to the power source. See S18737 instructions included with the plugs.

The recommended output cable sizes can be found in the Table below.

Machine

Up to 100 ft.

100 to 150 ft.

150 to 200 ft.

200 to 250 ft.

Size

(30 m)

(30 – 46 m)

(46 – 61 m)

(61 – 76 m)

600-I

2/0 (68 mm2)

3/0 (86 mm2)

3/0 (86 mm2)

4/0 (108 mm2)

 

 

 

 

 

IDEALARC R3R 600-I

Image 9
Contents Idealarc R3R California Proposition 65 Warnings SafetyElectric Shock can kill Cylinder may explode if damaged Sûreté Pour Soudage a L’Arc Précautions DE Sûreté Thank You Table of Contents Technical Specifications R3R 600-I K1381 InstallationInput Power Connection Warning InstallationDuty Cycle Output ConnectionsOperation Output Current Control Dial 2OPERATIONB-2Optional Equipment AccessoriesRoutine Maintenance MaintenancePower Rectifier Replacement Pocket AmptrolHOW to USE Troubleshooting Guide TroubleshootingFunction Problems Troubleshooting Troubleshooting Troubleshooting Problems Possible Cause Recommended Idealarc Procedure for Replacing PC Boards Troubleshooting ProceduresChecking Current Control Rheostat on Machine Power Silicon Controlled REC- Tifier Test Idealarc R3R-400, 500-I, 500 & 600-I Wiring Diagram Wiring DiagramsR3R K817 or K817R Dimension PrintPrecaucion Aviso DE