Lincoln Electric IM610-A manual Shielding Gas, Making a Weld

Page 18

B-5

 

OPERATION

 

B-5

 

FIGURE B.5

FIGURE B.6

Gun Handle

Gas Diffuser/

Contact Tip

Gas Nozzle

Shielding Gas

When using the GMAW process, a cylinder of shield- ing gas, must be obtained. Refer to the ACCES- SORIES section for more information about selecting gas cylinders for use with the SP-175 Plus. Be sure to observe all cylinder handling and use precau- tions.

1.For CO2, open the cylinder very slowly. For argon- mixed gas, open cylinder valve slowly a fraction of a turn. When the cylinder pressure gauge pointer stops moving, open the valve fully.

2.If using a regulator with an adjustable flow meter, press the gun trigger and adjust the flow to give 15

– 20 cubic ft per hour (CFH) (7 – 10 I/min) [use 20 -– 25 CFH (10 – 12 I/min) when welding out of

position or in a drafty location for CO2]. For argon mixed gas, press the gun trigger to release gas pressure, and adjust the flow to give 25 – 30 CFH (12 – 14 I/min).

3.Keep the cylinder valve closed, except when using the SP-175 Plus. When finished welding:

a) Close the cylinder valve to stop gas flow.

b) Depress the gun trigger briefly to release the pressure in the gas hose.

c) Turn off the SP-175 Plus.

Making A Weld

1.See Recommended Processes And Equipment section for selection of welding wire and shielding gas and for range of metal thicknesses that can be welded.

2.See the Application Chart on the inside of wire feed section door for information on setting the SP-175 Plus controls.

3.Set the Voltage (“V”) and Wire Speed (“oloʼ”) con- trols to the settings suggested for the welding wire and base metal thickness being used.

Contact Tip

Wire Electrode

3/8" – 1/2" Electrical Stickout

4.Check that the polarity is correct for the welding wire being used and that the gas supply, if required, is turned on.

5.When using Innershield electrode, remove the gas nozzle and install the gasless nozzle. This will improve visibility of the arc and protect the gas dif- fuser from weld spatter. Refer to the MAINTE- NANCE section for details on nozzle replacement.

6.Refer to Figure B.7. Connect work clamp to metal to be welded. Work clamp must make good elec- trical contact to the workpiece. The workpiece must also be grounded as stated in “Arc Welding Safety Precautions” in the beginning of this manu- al.

7.Position gun over joint. End of wire may be lightly touching the work.

8.Lower welding helmet, close gun trigger, and begin welding. Hold the gun so the contact tip to work distance is about 3/8 inch (10 mm).

FIGURE B.7

GUN CABLE

WORKPIECE

ARC

WORK CLAMP

SP-175 PLUS

Image 18
Contents SP-175 Plus Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Installation Installation Safety PrecautionsRead entire installation section before starting Identify and Locate ComponentsSelect Suitable Location Work Clamp InstallationWork Cable Installation StackingGUN Installation Connecting Gun Cable to the SP-175 PlusGAS Connection Gas Solenoid Inlet Fitting Power Input Cable Input ConnectionsLine Cord Connection Electrical Input Connection for Rated OutputVolt Input Connection Fumes and Gases can be dangerous Observe all safety information throughout this manualOperation Welding Sparks can cause fire or explosionGeneral Description Controls and SettingsDesign Features Advantages Welding CapabilityWire Loading Welding OperationsSequence of Operation Friction Brake Adjustments Wire ThreadingShielding Gas Making a WeldChanging Machine Over to Feed Other Wire Sizes Cleaning Tip And NozzleProcess Guidelines Output Overload Wire Feed Overload ProtectionOverload Protection Thermal ProtectionARC-WELDING Circuit Learning to WeldLearning to Weld SELF-SHIELDED Fcaw Welding ARCGmaw MIG Welding ARC Process SelectionFor Gmaw MIG Process For Fcaw Innershield Process Common MetalsJoint Types and Positions Butt WeldsWelding In The Vertical Position PenetrationFillet Welds Vertical-down Welding Machine SET UP for the SELF-SHIELDED Fcaw ProcessWelding Techniques for the Self Shielded Fcaw Process Correct Welding PositionCorrect Electrical Stickout ESO Correct Welding SpeedHelpful Hints PracticeMachine SET UP for the Gmaw MIG Process Welding Techniques for the Gmaw MIG ProcessFigure B.24 To Eliminate a Ropy Convex Bead in order of importance Troubleshooting WeldsTo Correct Poor Penetration in order of impor- tance To Eliminate Stubbing* in order of importanceProper Gun Handling Application Chart K1799-1 Argon-Mixed Gas Adjustable Regulator and Hose Kit AccessoriesOptional Accessories K586-1 Deluxe Adjustable Gas Regulator Hose KitReplacement Parts Innershield Fcaw ConversionItems Requiring no Maintenance MaintenanceMaintenance Safety Precautions Routine and Periodic MAINTE- NanceFor Magnum 100L GUN GUN and Cable MaintenanceConfiguration of Components in Wire Feeding System Contact Tip Cable Liner Drive RollChanging the Contact TIP Changing Drive RollRoll onto the drive shaft SP-175 Plus Changing Liner Liner trim lengthGUN Handle Parts Figure D.3 SP-125 PlusTroubleshooting HOW to USE Troubleshooting GuideProblems Possible Areas Symptoms Misadjustments Recommended Course of ActionGAS Flow Problems Welding Problems Wiring Diagrams SP-175 Plus Wiring Diagram CodePage Need Welding Training? How To Read Shop DrawingsNew Lessons in Arc Welding $700.00Precaucion Warnung