Lincoln Electric IM806 manual Accessories, K1745-1 Single GAS Cylinder Holder

Page 23

C-1

ACCESSORIES

C-1

 

 

 

OPTIONAL EQUIPMENT (Field Installed)

K957-1 HEAVY DUTY, TWO WHEEL TRAILER FOR SMALL WELDERS - For road, off-road and in-plant and yard towing. (For highway use, consult applicable federal, state and local laws regarding requirements for brakes, lights, fenders, etc.). Order:

K957-1 Trailer

K958-1 Ball Hitch

K958-2 Lunette Eye Hitch

K959-2 Fender & Light Kit

K965-1 Cable Storage Rack

K889-2 & -3 Two-Wheel Undercarriage - For moving by hand. Overall Width 29 in (.74m) Both have pneu- matic tires. Puncture proof tires included with K889-3.

K1631-1 Puncture Proof Wheel Kit - For converting K889-2 to puncture proof pneumatic tires.

K893-1 Caster for Undercarriage - Mounts to the front of the K889-2 to allow easy movement on smooth surfaces. Includes 6” diameter hard rubber wheel and convenient toe-on,toe-off locking brake.

K933-1 Four Wheel Undercarriage - For Hand Moving. Rear pneumatic tires, front molded wheels.

K934-1 Cylinder Brackets - For use with K933-1. for transporting either one LPG fuel cylinder or one weld- ing gas cylinder.

K1737-1 FOUR WHEEL ALL-TERRAIN UNDER- CARRIAGE - For moving by hand at construction sites. Heavy duty puncture resistant pneumatic tires.

K1770-1 UNDERCARRIAGE (FACTORY) - For mov- ing by hand on a smooth surface. One or two gas cylinders can be mounted on the rear of the undercar- riage with the installation of K1745-1 Cylinder Holder(s). Heavy duty puncture resistant pneumatic tires and front caster.

K1745-1 SINGLE GAS CYLINDER HOLDER

For use on K1770-1 Undercarriage. One or two may be installed on an undercarriage.

K1788-1 ROLL CAGE - Gives added damage protection.

K886-1 Canvas Cover -To protect the Weldmark 225 when not in use. Made from attractive red canvas material which is flame retardant, mildew resistant, and water repellent.

K802-R Power Plug Kit - Provides four 115V plugs rated at 15 amps each and one dual voltage, full KVA plug rated at 115/230V, 50 amps.

K802-N Power Plug Kit - Provides four 115V plugs rated at 20 amps each and one dual voltage, full KVA plug rated at 115/230V, 50 amps. (For K1418-2 or K1419-2 CSA machines and machines with GFCI recep- tacles, use K802-R).

K704 Accessory Kit - Includes 35 ft (10.7m) 2/0 AWG elec- trode cable, 30 ft. (9.1m) 2/0 AWG work cable, headshield with No. 12 filter, GC300 work clamp and Cooltong® 300 electrode holder. Cables are rated at 300 amps, 100% duty cycle.

K892-1 Remote Control Receptacle Kit - Includes a 6-pinMS-type (Amphenol) receptacle and a local-remote toggle switch that mounts in the case front. Required when using a K930-2 Tig Module with an optional Amptrol or when using a Remote Control.

K857 25 ft (7.5m) or K857-1100 ft. (30.4m) REMOTE CON- TROL - Portable control provides same dial range as the output control on the welder. Has a convenient 6 pin plug for easy connection to the welder.

K894-1 Spark Arrester Kit - Includes a heavy gauge steel, approved spark arrester and clamp for easy mounting to muffler exhaust pipe.

K1690-1 GFCI Receptacle Kit - Includes two UL approved 120V ground fault circuit interrupter duplex type receptacles with covers and installation instructions. Replaces the two fac- tory installed 120V duplex receptacles. Each receptacle of each GFCI duplex is rated at 20 amps, but the maximum total current from each GFCI duplex is limited to 20 amps. Two kits are required. See the MAINTENANCE section for detailed information on testing and resetting the GFCI receptacle.

K930-2 TIG Module - Provides high frequency and shielding gas control for AC and DC GTAW (TIG) welding applications. Its compact case is designed for easy carrying, complete with a handle. High frequency bypass is built in. The K938-1 Contactor Kit must be field installed in the TIG Module when used with a Weldmark 225. Additionally, the K936-3 control cable is required if remote control is used. If remote control is not used the K936-4 control cable is required.

K936-3 Remote Control Cable - Control cable for connecting the K930-2 TIG Module to a Weldmark 225 equipped with a K892-1 Remote Kit. 9-Socket to a grounded 115 V plug and a 6 pin MS-connector. (Contains circuits 2, 4, 31, 32, 75, 76, 77 and ground)

K939-1 Docking Kit - For mounting the K930-2 TIG Module unit on top of the Weldmark 225.

K1816-1 FULL KVA ADAPTER KIT - Plugs into the 120/240V NEMA 14-50R receptacle on the case front (which accepts 4- prong plugs) and converts it to a NEMA 6-50R receptacle, (which accepts 3-prong plugs.)

WELDMARK 225

Image 23
Contents Weldmark California Proposition 65 Warnings SafetyElectric Shock can kill Cylinder may explode if damaged Sûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Weldmark InstallationHeight Width Depth Weight Specifications Lifting Installation InstructionsMachine Grounding Spark ArresterElectrode and Work Cables Gasoline PRE-OPERATION ServiceWelding Output Cables Total Combined LengthLocation / Ventilation Connection of Wire FeedersAngle of Operation High Altitude OperationConnection of K930- TIG Module to the Weldmark Additional Safety PrecautionsAuxiliary Power InstructionsMotor Starting Duplex ReceptaclesThese Devices Without Standby Power Connections Auxiliary Power While WeldingSimultaneous Welding and Power Connection of Weldmark 225 to Premises Wiring Operation Design FeaturesOther Features Engine FeaturesControl Switch 20 H.P. CommandPolarity Switch Range SwitchStopping the Engine BREAK-IN PeriodStick Constant Current Welding Wire Feed Welding Processes Constant VoltageWelding Process Duty CycleHigh K1745-1 Single GAS Cylinder Holder AccessoriesTIG Wire FeedRecommended Equipment StickEngine OIL Change MaintenanceSafety Precautions Routine MaintenanceRanger OIL Filter ChangeEngine Adjustments Gfci Receptacle Testing and Reset Ting Procedure HOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Troubleshooting Diagrams Weldmark 225 Wiring Diagram CodeConnection of Weldmark 225 to LN-7 & K240 Contactor KIT Weldmark 225 / LN-25 Across the ARC Connection DiagramM17215-2 30-98E Precaucion Warnung Manufactured by Lincoln Electric Company