MAINTENANCE | ||
|
|
|
1.Loosen by two or three turns, the vent screw (Figure D.1) on the fuel inlet connection.
Vent Screw
FIGURE D.1
2.Operate the electric fuel pump by turning the “Ignition” switch “ON” until fuel, free of air, flows from the vent point. Tighten the vent screw.
3.Contact your Perkins Engine repair facility if prob- lems persist.
EVERY DAY OR EVERY 8 HOURS |
|
| |||||||
| FIRST |
|
| ||||||
|
| EVERY 100 HOURS OR 3 MONTHS |
|
| |||||
|
|
| EVERY 200 HOURS OR 6 MONTHS |
|
| ||||
|
|
|
| EVERY 400 HOURS OR 12 MONTHS |
|
| |||
|
|
|
|
| EVERY 600 HOURS OR 18 MONTHS |
|
| ||
|
|
|
|
|
| ENGINE SERVICE (NOTE 2) |
|
| |
|
|
|
|
|
| MAINTENANCE ITEM | TYPE OR QUANTITY | ||
|
|
|
|
|
|
|
|
| |
I |
|
|
|
|
| Coolant level |
| ||
|
|
|
| I |
| Concentration of antifreeze | 50/50 Water/Ethylene Glycol | ||
|
|
|
|
| R | Coolant (NOTE 3) | 9.5qrts., 9.0L | ||
I |
|
|
|
|
| Engine oil level (NOTE 1) |
| ||
| R | R |
|
|
| Engine oil (NOTE 1 & 3) | 8.7qrts, 8.2L (including filter) | ||
| R | R |
|
|
| Engine oil filter | Perkins #140517000 | ||
| C | C |
|
|
| Drain water separator & fuel strainer |
| ||
|
|
|
| R |
| Fuel filter canister | Perkins #26560017 | ||
I |
|
|
|
|
| Tension of alternator drive belt |
| ||
|
|
|
| I |
| Alternator drive belt wear |
| ||
|
|
|
|
| R | Alternator drive belt | Perkins #080109080 | ||
| C | C |
|
|
| Air filter (earlier check may be req’d.) |
| ||
|
|
|
| R |
| Air filter element | Donaldson #P181050, Nelson #70206N | ||
|
| I |
|
|
| Check and adjust idle speed |
| ||
|
|
|
|
| I | Tighten cylinder head |
| ||
|
|
|
|
| I | Valve clearances | Intake .008", exhaust .008" | ||
|
|
|
|
| I | Electrical systems |
| ||
|
|
|
|
| I | All nuts and bolts for tightness |
| ||
|
|
|
| I |
| Injector performance | Contact Perkins | ||
I |
|
|
|
|
| Leaks or engine damage |
| ||
|
|
|
| I |
| Battery |
|
|
|
I = Inspect |
| C = Clean | R = Replace |
|
Notes:
(1)Consult Engine Operators Manual for oil recommendations.
(2)Consult Engine Operators Manual for additional maintenance schedule information.
(3)Fill slowly! Ensure correct quantity is used.
Above operations to be carried out by trained personnel with reference to the workshop manual where necessary.
These preventive maintenance periods apply to average conditions of operation. |
|
If necessary use shorter periods. | S25557 |
PIPELINER 200D