Lincoln Electric IM769 manual Idler Operation, Auxiliary Power

Page 15

B-4

OPERATION

B-4

 

 

 

When a forceful “digging” arc is required, usually for vertical and overhead welding, use a higher “Current Range Selector” setting and lower open circuit volt- age. For example: to obtain 175 amps and a forceful arc, set the “Current Range Selector” to the 240-160 position and the “Fine Current Adjustment” setting to get 175 amps.

CAUTION

DO NOT attempt to set the “Current Range Selector” between the five points designated on the nameplate.

------------------------------------------------------------------------

These switches have a spring loaded cam which almost eliminates the possibility of setting this switch between the designated points.

IDLER OPERATION

Start the engine with the “Idler” switch in the “High” position. Allow it to run at high idle speed for several minutes to warm the engine. See Specifications for operating speeds.

The idler is controlled by the “Idler” toggle switch on the welder control panel. The switch has two posi- tions as follows:

1.In the “High” position, the idler solenoid acti- vates, and the engine goes to high idle speed. The speed is controlled by the governor.

2.In the “Auto” / position, the idler oper- ates as follows:

When welding or drawing power for lights or tools (approximately 100-150 watts minimum) from the receptacle, the idler solenoid activates and the engine operates at high idle speed.

When welding ceases or the power load is turned off, a preset time delay of about 15 seconds starts. This time delay cannot be adjusted.

If the welding or power load is not re-started before the end of the time delay, the idler solenoid deacti- vates and reduces the engine to low idle speed.

AUXILIARY POWER

1.80kW of 120V DC auxiliary power at 35% duty cycle maximum is available at the receptacle located on the control panel.

PIPELINER 200D

Image 15
Contents Pipeliner 200D California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Installation Machine Grounding Safety PrecautionsExhaust Spark Arrester Location / VentilationImproperly mounted concentrated loads may PRE-OPERATION ServiceTrailers See Accessories Section Polarity Control and Cable SizesCooling System Battery ChargingOIL FuelOperation General DescriptionDesign Summary Cold Weather Starting Engine OperationControl of Welding Current Welder OperationEngine BREAK-IN Duty CycleIdler Operation Auxiliary PowerOptional Features Field Installed AccessoriesMaintenance Engine MaintenanceGeneral Instructions Nameplates Idler MaintenanceBearings Commutator and BrushesVent Screw Engine Service Note Maintenance Item Type or QuantityHOW to USE Troubleshooting Guide TroubleshootingPossible Areas SymptomsContact your local Lincoln Possible Areas Recommended SymptomsAuthorized Field Service Facility Course of ActionTroubleshooting Faulty Charging Loose fan belt Open Closed Electronic Idler Troubleshooting GuideEngine Picks Up Speed Engine Does Not Pick Up Wiring Diagram Diagrams K2464-1 Remote Control Wiring / Connection DiagramSkid Mounting Hole Dimension PrintPipeliner 200D Pipeliner 200D Precaucion Warnung