TROUBLESHOOTING

E-2

 

 

 

 

 

 

Observe all Safety Guidelines detailed throug out this manual

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

MISADJUSTMENTS

COURSE OF ACTION

 

 

 

 

 

 

PROBLEMS

Machine fails to hold the heat con-

1.

Rough or dirty commutator.

stantly.

 

 

 

2.

Brushes may be worn down to

 

 

limit.

 

3.

Field circuit may have variable

 

 

resistance connection or intermit-

 

 

tent open circuit due to loose, or

 

 

broken wire.

 

4.

Electrode lead or work lead con-

 

 

nection may be poor.

 

5.

Wrong grade of brushes may

 

 

have been installed on generator.

 

6.

Field rheostat may be making

 

 

poor contact and overheating.

 

 

 

Welder starts but fails to generate

1.

Generator or exciter brushes may

current.

 

be loose or missing.

 

2.

Exciter may not be operating.

 

3.

Field circuit of generator or

 

 

exciter may be open.

 

4.

Exciter may have lost excitation.

 

5.

Series field and armature circuit

 

 

may be open-circuited.

If all recommended possible areas of misadjustment have been checked and the problem persists,

Contact your local Lincoln Authorized Field Service Facility.

Welding arc is loud and spatters excessively.

1.Current setting may be too high.

2.Polarity may be wrong.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

PIPELINER 200D

Image 21
Contents Pipeliner 200D California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Installation Exhaust Spark Arrester Safety PrecautionsLocation / Ventilation Machine GroundingTrailers See Accessories Section PRE-OPERATION ServicePolarity Control and Cable Sizes Improperly mounted concentrated loads mayOIL Battery ChargingFuel Cooling SystemOperation General DescriptionDesign Summary Cold Weather Starting Engine OperationEngine BREAK-IN Welder OperationDuty Cycle Control of Welding CurrentIdler Operation Auxiliary PowerOptional Features Field Installed AccessoriesMaintenance Engine MaintenanceGeneral Instructions Bearings Idler MaintenanceCommutator and Brushes NameplatesVent Screw Engine Service Note Maintenance Item Type or QuantityHOW to USE Troubleshooting Guide TroubleshootingPossible Areas SymptomsAuthorized Field Service Facility Possible Areas Recommended SymptomsCourse of Action Contact your local LincolnTroubleshooting Faulty Charging Loose fan belt Open Closed Electronic Idler Troubleshooting GuideEngine Picks Up Speed Engine Does Not Pick Up Wiring Diagram Diagrams K2464-1 Remote Control Wiring / Connection DiagramSkid Mounting Hole Dimension PrintPipeliner 200D Pipeliner 200D Precaucion Warnung