Lincoln Electric IM769 manual Safety Precautions, Exhaust Spark Arrester, Location / Ventilation

Page 9

A-2

INSTALLATION

A-2

 

 

 

SAFETY PRECAUTIONS

WARNING

Do not attempt to use this equipment until you have thoroughly read the engine manufacturer’s manual supplied with your welder. It includes important safety precautions, detailed engine starting, operating and maintenance instructions, and parts lists.

------------------------------------------------------------------------

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts or electrode with skin or wet clothing.

Insulate yourself from work and ground

Always wear dry insulating gloves.

------------------------------------------------------------------------

ENGINE EXHAUST can kill.

• Use in open, well ventilated areas or vent exhaust outside.

------------------------------------------------------------------------

MOVING PARTS can injure.

Do not operate with doors open or guards off.

• Stop engine before servicing.

Keep away from moving parts.

------------------------------------------------------------------------

See additional warning information at

front of this operator’s manual.

-----------------------------------------------------------

EXHAUST SPARK ARRESTER

Some federal, state, or local laws may require that engines be equipped with exhaust spark arresters when they are operated in certain locations where unarrested sparks may present a fire hazard. The standard mufflers included with these welders do not qualify as spark arresters. When required by local reg- ulations, suitable spark arrester must be installed and properly maintained.

CAUTION

Use of an incorrect arrester may lead to engine dam- age or performance loss. Contact the engine manu- facturer for specific recommendations.

----------------------------------------------------------------------

LOCATION / VENTILATION

Always operate the welder with the doors closed. Leaving the doors open changes the designed air flow and may cause overheating.

The welder should be located to provide an unrestrict- ed flow of clean, cool air. Also, locate the welder so that engine exhaust fumes are properly vented to an outside area.

CAUTION

DO NOT MOUNT OVER COMBUSTIBLE SUR- FACES.

Where there is a combustible surface directly under stationary or fixed electrical equipment, the surface shall be covered with a steel plate at least

.06”(1.6mm) thick, which shall extend not more than 5.90”(150mm) beyond the equipment on all side.

------------------------------------------------------------------------

MACHINE GROUNDING

According to the United States National Electrical Code, the frame of this portable generator is not required to be grounded and is permitted to serve as the grounding means for cord connected equipment plugged into its receptacle.

Some state, local, or other codes or unusual operating circumstances may require the machine frame to be grounded. It is recommended that you determine the extent to which such requirements may apply to your particular situation and follow them explicitly. A machine grounding stud marked with the symbol is provided on the welding generator frame foot. In general, if the machine is to be grounded it should be connected with a #8 or larger copper wire to a solid earth ground such as a metal water pipe going into the ground for at least ten feet and having no insulat- ed joints, or to the metal framework of a building which has been effectively grounded. The U.S. National Electrical Code lists a number of alternate means of grounding electrical equipment.

LIFT BAIL

A lift bail is provided for lifting with a hoist.

WARNING

 

• Lift only with equipment of

 

adequate lifting capacity.

 

• Be sure machine is stable

 

when lifting.

 

• Do not lift this machine using

 

lift bale if it is equipped with a

 

heavy accessory such as trail-

 

er or gas cylinder.

FALLING

• Do not lift machine if lift bail is

EQUIPMENT can

damaged.

cause injury.

• Do not operate machine while

 

suspended from lift bail.

------------------------------------------------------------------------

PIPELINER 200D

Image 9
Contents Pipeliner 200D California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Installation Exhaust Spark Arrester Safety PrecautionsLocation / Ventilation Machine GroundingTrailers See Accessories Section PRE-OPERATION ServicePolarity Control and Cable Sizes Improperly mounted concentrated loads mayOIL Battery ChargingFuel Cooling SystemOperation General DescriptionDesign Summary Cold Weather Starting Engine OperationEngine BREAK-IN Welder OperationDuty Cycle Control of Welding CurrentIdler Operation Auxiliary PowerOptional Features Field Installed AccessoriesMaintenance Engine MaintenanceGeneral Instructions Bearings Idler MaintenanceCommutator and Brushes NameplatesVent Screw Engine Service Note Maintenance Item Type or QuantityHOW to USE Troubleshooting Guide TroubleshootingPossible Areas SymptomsAuthorized Field Service Facility Possible Areas Recommended SymptomsCourse of Action Contact your local LincolnTroubleshooting Faulty Charging Loose fan belt Open Closed Electronic Idler Troubleshooting GuideEngine Picks Up Speed Engine Does Not Pick Up Wiring Diagram Diagrams K2464-1 Remote Control Wiring / Connection DiagramSkid Mounting Hole Dimension PrintPipeliner 200D Pipeliner 200D Precaucion Warnung