TROUBLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
|
|
|
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
No welding power output. | 1. | Poor work lead connection to |
Auxiliary Power OK. |
| work. Make sure work clamp is |
|
| tightly connected to clean base |
|
| metal. |
| 2. | "Weld Terminals" switch in wrong |
|
| position. Place switch in "Weld |
|
| Terminals On" position when |
|
| welding without control cable. |
| 3. | Faulty PC board. |
| Welder has output but no control. | 1. | Poor remote/control cable connec- |
| |||
|
|
| tion to |
| |||
|
|
| Check connections. |
|
|
|
|
|
| 2. | Faulty remote cable or faulty wire |
| |||
|
|
| feeder or wire feeder cable. |
| |||
|
|
| Replace if necessary. |
| |||
|
| 3. | Faulty control potentiometer or PC |
| |||
|
|
| board. |
|
|
|
|
|
|
|
|
|
| If all recommended possible | areas |
|
|
|
|
|
| ||
| Wire feeder does not work when 1. | Wire Feeder Power circuit breaker of misadjustment have | been | ||||
| control cable is connected to 14 pin |
| open. Check 42V beaker and checked and the problem persists, | ||||
| connector. |
| reset if tripped. |
|
| Contact your local Lincoln | |
|
| 2. | Faulty control cable. Repair or Authorized Field Service Facility. | ||||
|
|
| replace cable. |
|
|
|
|
|
| 3. | Faulty wire feeder. | Replace wire |
| ||
|
|
| feeder. |
|
|
|
|
|
|
|
|
|
|
| |
| No auxiliary power. | 1. | Open circuit breakers. Reset |
| |||
|
|
| breakers. If breakers keep trip- |
| |||
|
|
| ping, reduce power draw. |
| |||
|
| 2. | Faulty connections to auxiliary |
| |||
|
|
| receptacles. Check connections. |
| |||
|
| 3. | RCD tripped. Clear any ground |
| |||
|
|
| fault and reset RCD circuit by |
| |||
|
|
| pressing "Reset" button. |
| |||
|
| 4. | Faulty PC board or welder alterna- |
| |||
|
|
| tor. |
|
|
|
|
CAUTION